Journal of back and musculoskeletal rehabilitation

Walking speed and inter-limb vertical loading asymmetry after unilateral total hip replacement: A secondary analysis of an open motion-capture dataset.

Alex Kubiak, Farzad Haji Boloori, Mccord Meyers

Department of Surgery, Kansas City University School of Medicine, Kansas City, MO, USA.

Key points

From the paper's conclusion
  • Whether asymmetry differs at a faster speed is unclear.ObjectiveTo examine whether operated-versus-contralateral vertical ground reaction force (vGRF) asymmetry differs between self-selected and fast walking 1-6 years after unilateral THR.MethodsSecondary analysis of an open motion-capture dataset.

Abstract

BackgroundInter-limb loading asymmetry after total hip replacement (THR) is usually assessed at a self-selected walking speed. Whether asymmetry differs at a faster speed is unclear.ObjectiveTo examine whether operated-versus-contralateral vertical ground reaction force (vGRF) asymmetry differs between self-selected and fast walking 1-6 years after unilateral THR.MethodsSecondary analysis of an open motion-capture dataset. Eighty unilateral THR patients walked at self-selected and fast speeds. The primary outcome was the within-patient change in the weight-acceptance vGRF symmetry index (ΔSI), tested for equivalence against ±10 and ±5 percentage-point (pp) margins. Secondary analyses examined measured speed, other vGRF and hip-moment indices, and waveforms.ResultsWalking speed increased by 0.52 m/s. ΔSI was 0.39 pp (90% CI -0.61 to 1.38), equivalent to zero at both margins (P < 0.001). Within patients, measured speed was not associated with SI (0.56 pp per m/s, 95% CI -2.36 to 3.48). Six of 80 patients (7.5%) changed by more than 10 pp, and between-patient variation in ΔSI did not exceed that expected from measurement error. No vGRF waveform region showed a speed-dependent change in asymmetry; late-stance hip flexor-moment asymmetry was larger at fast speed (77-96% of stance).ConclusionIn pain-free patients 1-6 years after THR who could walk fast, vertical loading asymmetry was similar at self-selected and fast speeds. Whether this holds for joint-level kinetics, earlier rehabilitation or lower-functioning patients requires further study.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Walking speed and inter-limb vertical loading asymmetry after unilateral total hip replacement: A secondary analysis of an open motion-capture dataset — Science Skim