Ergonomic evaluation of an age-friendly foot dorsiflexion stretching device for adults aged 55 years or older.
Chi-Hung Lo
Department of Industrial Design, Tunghai University, Taichung.
Key points
From the paper's conclusion- BackgroundSupported stretching devices may facilitate accessible lower-limb movement, but candidate settings should be evaluated without equating physiological responses with functional benefit.ObjectiveTo examine physiological and perceptual responses to a foot dorsiflexion stretching prototype and identify candidate settings for further evaluation.MethodsThe within-subject evaluation involved 20
Abstract
BackgroundSupported stretching devices may facilitate accessible lower-limb movement, but candidate settings should be evaluated without equating physiological responses with functional benefit.ObjectiveTo examine physiological and perceptual responses to a foot dorsiflexion stretching prototype and identify candidate settings for further evaluation.MethodsThe within-subject evaluation involved 20 adults aged 55 years or older. Prototype footplate inclinations of 22°, 24° and 26° preceded 30-70-s duration conditions at 22° in a fixed sequence. Walking surface electromyography (sEMG) following exposure was evaluated separately for four right-leg muscles and for dynamic and static modes. Frontal electroencephalography (EEG) followed walking. Available tabulated summaries were analysed using participant-level baseline differences, sample standard deviations and nominal 95% confidence intervals. Eight semantic descriptors were reported individually.ResultsAt 22°, mean tabulated walking-amplitude changes were positive for all four muscles in both modes; at 26°, they were negative. Comfortable-item means were 4.55 in both modes at 22° and 4.60/4.50 at 60 s. Several, but not all, profiles were largest around 50-60 s. Matching physiological entries at 22° and 60 s did not provide independent validation. Record inconsistencies and incomplete measurement documentation limited interpretation.ConclusionsA 22° prototype footplate inclination and 60-s exposure are candidate settings only for this prototype, sample and sequence. The findings do not establish an optimum, mode-specific functional benefits, clinical efficacy or safety thresholds.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Seat-Height Effects During Seated Shoe Donning in Older Adults: A Multi-Stage Ergonomic Evaluation Integrating Muscle Activity, Postural Exposure, and Subjective Comfort.Sensors (Basel, Switzerland) · 2026
- Retrofittable Surface Modifications to Everyday Furniture Alter Hand-Environment Interaction During Sit-to-Stand Movements in Older Adults.Bioengineering (Basel, Switzerland) · 2026
- Lower limb exoskeletons for older adults: key assistance parameters and evaluation of ankle assistive strategies via musculoskeletal modelling.Frontiers in sports and active living · 2026
- Ankle-Derived Gait Features Did Not Consistently Improve Discrimination of Non-Slowness Frailty Deficits Beyond Timed Up and Go Time in FRAILPOL: Implications for Geriatric RehabilitationJournal of Clinical Medicine · 2026
- Low‐threshold cutaneous mechanoreceptors on the foot sole have enhanced sensitivity when skin temperature is elevatedThe Journal of Physiology · 2026
- Voluntary activation of the ankle dorsiflexors is overestimated using the interpolated twitch technique with electrical stimulation.European journal of applied physiology · 2026