Influence of corrosion behavior of Ti-based PVD coatings on 316L SS for biomedical implants.
M Shunmuga Priyan, G Godwin
Department of Mechanical Engineering, Loyola Institute of Technology & Science, Thovalai, India.
Key points
From the paper's conclusion- The enhanced corrosion resistance was attributed to the protective and stable nature of the Ti-based coating layer.ConclusionThe TiCoCr, TiN, and TiO2 PVD coatings significantly enhanced the corrosion resistance of 316L SS in simulated physiological environments.
Abstract
Background316L stainless steel (SS) is widely used in biomedical implant applications because of its excellent mechanical properties, corrosion resistance, biocompatibility, and cost-effectiveness. However, its long-term performance in physiological environments is limited by localized corrosion, ion release, and inadequate surface interactions with biological tissues. Surface modification using Ti-based physical vapor deposition (PVD) coatings has emerged as a promising strategy to enhance the corrosion resistance and durability of implant materials.ObjectiveThis study aimed to investigate the effect of Ti-based PVD coatings, namely TiCoCr, TiN, and TiO2, on the corrosion behavior of 316L SS under simulated physiological conditions.MethodsTiCoCr, TiN, and TiO2 coatings were deposited onto 316L SS substrates using the PVD technique. The corrosion performance of the coated and uncoated samples was evaluated in phosphate-buffered saline (PBS), Hanks' solution, and Ringer's solution at 37 °C. Electrochemical corrosion parameters, including corrosion potential and corrosion current density, were analyzed to assess the effectiveness of the coatings.ResultsAll Ti-based coatings improved the corrosion resistance of 316L SS compared with the uncoated substrate. Among the investigated coatings, the TiCoCr coating deposited for 90 min exhibited the best corrosion performance. In Ringer's solution, the coating showed a corrosion potential of -0.0504 V and a corrosion current density of 4.74 × 10-6 A/cm2. In Hanks' solution, the same coating demonstrated a corrosion potential of -0.1815 V and a corrosion current density of 5.0537 × 10-6 A/cm2. The enhanced corrosion resistance was attributed to the protective and stable nature of the Ti-based coating layer.ConclusionThe TiCoCr, TiN, and TiO2 PVD coatings significantly enhanced the corrosion resistance of 316L SS in simulated physiological environments. Among them, the TiCoCr coating demonstrated superior corrosion protection, indicating its strong potential for improving the long-term reliability and performance of biomedical implants.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrophoretic deposition of CaP-TiSiN composite coatings on 316L stainless steel: corrosion resistance and in vitro cytocompatibility.Journal of medical engineering & technology · 2026
- Investigations of CrN/TiO2 Coatings Obtained in the Hybrid PVD/ALD Process on 316L Steel SubstratesMaterials · 2026
- Multifunctional nanosilver-reinforced biocomposite coatings for metallic surface protectionExperimental and Theoretical NANOTECHNOLOGY · 2026
- Corrosion and wear-corrosion behavior of the nitrided layer on selective laser melting fabricated TC4 alloy by hollow cathodic plasma source nitridingJournal of Materials Research and Technology · 2025
- Relative assessment of strontium-zinc-phosphate chemical conversion coatings on titanium for augmenting bioactivity: Effect of microstructure.Journal of biomaterials applications · 2026
- Corrosion Resistance of Different Coatings on Titanium Surface: A Systematic ReviewMaterials and Corrosion · 2026