Technology and health care : official journal of the European Society for Engineering and Medicine

Immediate responses to stimulation of trigeminal-associated sites using conventional suction-type and wearable silicone SSP electrodes: An exploratory randomized three-arm study in healthy adults.

Hyunju Moon, Wonsik Bae

Department of Physical Therapy, Kaya University, Gimhae, Republic of Korea. · Department of Physical Therapy, Kyungnam College of Information & Technology, Busan, Republic of Korea.

Randomised

Key points

From the paper's conclusion
  • BackgroundComparative evidence regarding the immediate subjective and physiological responses to conventional suction-type and wearable conductive silicone silver spike point (SSP) electrodes remains limited.ObjectiveTo compare responses to conventional SSP stimulation at V1-associated sites and wearable silicone SSP stimulation at V3-associated sites with a nonequivalent no-current control.Method

Abstract

BackgroundComparative evidence regarding the immediate subjective and physiological responses to conventional suction-type and wearable conductive silicone silver spike point (SSP) electrodes remains limited.ObjectiveTo compare responses to conventional SSP stimulation at V1-associated sites and wearable silicone SSP stimulation at V3-associated sites with a nonequivalent no-current control.MethodsFifty-four healthy young adults were randomized to control, conventional SSP, or silicone SSP groups (18 per group). Conventional electrodes were applied without current in the control group, whereas both active groups received 20 min of stimulation. The primary outcome was pre-to-post change in the Karolinska Sleepiness Scale (KSS). Exploratory secondary outcomes included electroencephalography (EEG), heart rate variability (HRV), and masseter electromyography (EMG). Analyses included mixed repeated-measures ANOVA and Welch ANOVA with Dunnett T3-adjusted comparisons.ResultsA significant time × group interaction was observed for KSS [F(2, 51) = 4.693, p = .013, partial η2 = .155]. Mean ± SD changes were 0.53 ± 1.77, 1.14 ± 1.95, and 2.92 ± 3.28 points in the control, conventional SSP, and silicone SSP groups, respectively. Post hoc analysis showed a significant difference between the silicone SSP and control groups (mean difference, 2.389; 95% CI, 0.154-4.624; adjusted p = .034), but not between the two active stimulation groups (adjusted p = .162). No significant time × group interactions were observed for EEG, HRV, or EMG.ConclusionKSS changes differed between silicone SSP and no-current control, but superiority or equivalence relative to conventional SSP was not established. The simultaneous differences in stimulation site and electrode design prevent attribution of the observed findings to either factor independently.

Read the paper

Discussion