Effects of a wearable chair on surgeon fatigue during laparoscopic inguinal hernia repair: A pilot randomized controlled trial.
Shoichi Shinohara, Hiroshi Kawahira, Kosuke Oiwa, Yuji Kaneda, Yoshitaka Maeda, Tsuneari Takahashi, Hironori Yamaguchi, Naohiro Sata
Department of Surgery, Hitachiomiya Saiseikai Hospital, Hitachiomiya, Japan. · Department of Surgery, Division of Gastroenterological, General and Transplant Surgery, Jichi Medical University, Shimotsuke, Japan.
Key points
From the paper's conclusion- Wearable chairs may reduce fatigue, but clinical evidence remains limited.ObjectiveTo evaluate wearable chair effects on surgeon fatigue during laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair.MethodsTwelve patients undergoing elective TAPP repair were randomized to wearable chair or control groups (n = 6 each).
Abstract
BackgroundSurgeons experience physical and mental fatigue during prolonged standing. Wearable chairs may reduce fatigue, but clinical evidence remains limited.ObjectiveTo evaluate wearable chair effects on surgeon fatigue during laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair.MethodsTwelve patients undergoing elective TAPP repair were randomized to wearable chair or control groups (n = 6 each). The primary endpoint was the intraoperative low-frequency/high-frequency (LF/HF) ratio derived from heart rate variability. Secondary endpoints included visual analog scale (VAS) assessments and surgical outcomes.ResultsNo statistically significant between-group difference was detected in the primary LF/HF ratio (p = 0.485). Subjective physical fatigue was significantly lower in the wearable chair group (p = 0.045). Mental fatigue, comfort, and surgical maneuverability showed no significant differences (p = 0.065, 0.054, and 0.066, respectively). Surgical duration, blood loss, postoperative hospital stay, and complication rates showed no significant differences (p = 0.423, 0.345, 0.091, and 1.000, respectively).ConclusionIn this small exploratory pilot study, a wearable chair may reduce subjective physical fatigue, a secondary outcome, although no statistically significant difference was detected in the primary LF/HF endpoint. Larger multicenter studies are needed to confirm these preliminary findings.Trial registration: UMIN-CTR (UMIN000057932).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stress Exposure of Camera-Holders Versus Primary Surgeons During Laparoscopic Surgery: Best Evidence Analysis.European journal of pediatric surgery : official journal of Austrian Association of Pediatric Surgery ... [et al] = Zeitschrift fur Kinderchirurgie · 2026
- Surgeon task load, ergonomics, and clinical outcomes in laparoscopic versus robotic-assisted inguinal hernia repair: a systematic review and meta-analysis of randomized controlled trials.Journal of robotic surgery · 2026
- Robotic versus laparoscopic minimally invasive inguinal hernia repair: randomized clinical trial (the ROGER trial)British journal of surgery · 2025
- Surgeon Ergonomics of Lateral Lumbar Interbody Fusion Across Four Patient Positions: A Proof-of-Concept Simulation Study Using Motion Capture and Electromyography.Global spine journal · 2026
- Ergonomic and Workload Challenges in Minimally Invasive Liver Surgery: A Comparative Pilot Study of Robotic and Laparoscopic Approaches.Asian journal of endoscopic surgery · 2026
- Intraoperative Physiological Activation: Phase-Associated Surgeon Heart Rate Variation During Laparoscopic Nephrectomy.Healthcare (Basel, Switzerland) · 2026