Wire-assisted trans-urethral exchange of uReteral stent (WATERS): A cost-effective alternative to the snare-loop technique in gynecological malignancies.
Pierluigi Barbieri, Alessandro Posa, Anna Rita Scrofani, Alessandra De Filippis, Alessandro Cina, Alessandro Maresca, Andrea Contegiacomo, Roberto Iezzi
Radiologia d'Urgenza e Interventistica, Fondazione Policlinico Universitario Agostino Gemelli - IRCCS, Rome, Italy.
Key points
From the paper's conclusion- Double-J stent replacement can be easily performed using this wire-loop technique, lowering procedural costs without hindering patient safety regarding radiation dose and procedural complications.
Abstract
OBJECTIVES: To retrospectively evaluate the feasibility and safety of wire-assisted trans-urethral exchange of double-J ureteral stents as a cost-effective and easy to learn alternative to the traditional snare-loop technique in patients with gynecological malignancies. MATERIALS AND METHODS: Between December 2021 and March 2025, all female patients undergoing trans-urethral stent replacement or removal were retrospectively reviewed; among them, 76 female patients (mean age 60 years, range 33-86 years) underwent retrograde trans-urethral encircling of double-J ureteral stents using a wire-assisted technique. Stents were mostly placed in case of primary or secondary neoplastic urinary tract obstruction. A 14-F Foley catheter was firstly inserted in the bladder and then exchanged on a hydrophilic guide-wire with a 7-F × 10 cm angiographic sheath; a 0.018" hydrophilic guide-wire was folded into a U-shape and inserted into the bladder through the sheath, making it an adjustable-in-size loop, fit for stent retrieval. Procedural time (time between the start and the end of the procedure), radiation dose (in terms of Dose-Area-Product, DAP), and complication rates were examined. Data were compared to the ones from a retrospective cohort of patients who underwent ureteral stent replacement with the snare-loop technique during the same time period. RESULTS: Technical success was achieved in 95% of cases, without major complications. Radiation dose and mean fluoroscopy were similar to the snare-loop technique for all the subgroups taken in considerations. Total cost of the used materials were lower for the wire-assisted technique than the snare-loop one. CONCLUSION: Double-J stent replacement can be easily performed using this wire-loop technique, lowering procedural costs without hindering patient safety regarding radiation dose and procedural complications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Selective Omission of Ureteral Access Sheath in Retrograde Intrarenal Surgery: Surgical and Safety Outcomes from a Single-Center Retrospective Cohort StudyJournal of Clinical Medicine · 2026
- A novel and simple modification for implantation of double-J stents during modified laparoscopic Lich Gregoir ureteral reimplantationBMC Urology · 2026
- Urinary procedures in gynecologic oncology: a comprehensive literature review and management algorithm proposal.International journal of gynecological cancer : official journal of the International Gynecological Cancer Society · 2026
- Robot-assisted retrograde intrarenal surgery for residual superior calyceal stone after multiple endourological interventions: a case report.International journal of surgery case reports · 2026
- Suction versus traditional ureteral access sheaths in retrograde intrarenal surgery: an updated systematic review and meta-analysis of stone-free rates and complications.World journal of urology · 2026
- Severe Encrustation, Fragmentation, and Urethral Extrusion of a Forgotten Ureteral Stent Managed With a Minimally Invasive Approach.Clinical case reports · 2026