Urologia

Wire-assisted trans-urethral exchange of uReteral stent (WATERS): A cost-effective alternative to the snare-loop technique in gynecological malignancies.

Pierluigi Barbieri, Alessandro Posa, Anna Rita Scrofani, Alessandra De Filippis, Alessandro Cina, Alessandro Maresca, Andrea Contegiacomo, Roberto Iezzi

Radiologia d'Urgenza e Interventistica, Fondazione Policlinico Universitario Agostino Gemelli - IRCCS, Rome, Italy.

Observational

Key points

From the paper's conclusion
  • Double-J stent replacement can be easily performed using this wire-loop technique, lowering procedural costs without hindering patient safety regarding radiation dose and procedural complications.

Abstract

OBJECTIVES: To retrospectively evaluate the feasibility and safety of wire-assisted trans-urethral exchange of double-J ureteral stents as a cost-effective and easy to learn alternative to the traditional snare-loop technique in patients with gynecological malignancies. MATERIALS AND METHODS: Between December 2021 and March 2025, all female patients undergoing trans-urethral stent replacement or removal were retrospectively reviewed; among them, 76 female patients (mean age 60 years, range 33-86 years) underwent retrograde trans-urethral encircling of double-J ureteral stents using a wire-assisted technique. Stents were mostly placed in case of primary or secondary neoplastic urinary tract obstruction. A 14-F Foley catheter was firstly inserted in the bladder and then exchanged on a hydrophilic guide-wire with a 7-F × 10 cm angiographic sheath; a 0.018" hydrophilic guide-wire was folded into a U-shape and inserted into the bladder through the sheath, making it an adjustable-in-size loop, fit for stent retrieval. Procedural time (time between the start and the end of the procedure), radiation dose (in terms of Dose-Area-Product, DAP), and complication rates were examined. Data were compared to the ones from a retrospective cohort of patients who underwent ureteral stent replacement with the snare-loop technique during the same time period. RESULTS: Technical success was achieved in 95% of cases, without major complications. Radiation dose and mean fluoroscopy were similar to the snare-loop technique for all the subgroups taken in considerations. Total cost of the used materials were lower for the wire-assisted technique than the snare-loop one. CONCLUSION: Double-J stent replacement can be easily performed using this wire-loop technique, lowering procedural costs without hindering patient safety regarding radiation dose and procedural complications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers