Anaesthesia and intensive care

Central venous access device complications: A review of 163 incidents reported to webAIRS.

Fergus Davidson, Catherine Caldwell, Yasmin Endlich

Department of Anaesthesia and Pain Management, Concord Hospital, Concord, NSW, Australia. · Anaesthesia Department, Wellington Hospital, Wellington, New Zealand.

Review

Key points

From the paper's conclusion
  • Between 2009 and 2023, 163 incidents involving a central venous access device were reported by Australian and New Zealand anaesthetists to webAIRS, a web-based anaesthetic incident voluntary reporting system.

Abstract

Central venous access device insertion is a valuable intervention for the perioperative management of complex patients or surgeries. While most insertions are without complication, there are repeated and often preventable adverse events that can result in serious harm or death. Between 2009 and 2023, 163 incidents involving a central venous access device were reported by Australian and New Zealand anaesthetists to webAIRS, a web-based anaesthetic incident voluntary reporting system. Most incidents occurred in older patients (49.7% were older than 60 years of age) and in patients with greater clinical complexity (82.2% were classified as the American Society of Anesthesiologists status III or higher), involved experienced anaesthetists (81.6% were at Post Fellowship level or above), occurred during daylight hours (76.6%) and involved staff who had been on duty 10 hours or less (78.5%). Eighteen reports described potential allergic reactions during central venous access device insertion, with six confirmed cases of anaphylaxis. There were 29 reports of arterial injury, 19 of which occurred despite ultrasound guidance during insertion. On four occasions, respiratory arrest followed inadvertent injection of muscle relaxant remaining in peripherally inserted central catheter line dead space. While most incidents resulted in minor or no effect (63.1%), there was a 28% incidence of temporary disability, 3% incidence of death and a 1.2% incidence of permanent disability. The event was assessed as preventable in 68.7% of incidents. Strategies to enhance the standardisation of central venous access device insertion and maintenance protocols, and routine use of measures to prevent these complications are discussed.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Central venous access device complications: A review of 163 incidents reported to webAIRS — Science Skim