Acta radiologica (Stockholm, Sweden : 1987)

Cochlear modiolus T1 hyperintensity as an additional imaging marker of posterior fossa subarachnoid hemorrhage.

Eiji Matsusue, Chie Inoue, Kensuke Matsumoto, Yuji Kamata, Tomohiko Tanino, Kazuhiko Nakamura, Shinya Fujii

Department of Radiology, Tottori Prefectural Central Hospital, Tottori, Japan. · Division of Radiology, Department of Multidisciplinary Internal Medicine, Tottori University, Tottori, Japan.

Key points

From the paper's conclusion
  • BackgroundCochlear modiolus (CM) T1 hyperintensity on thin-slice 3 T T1-weighted (T1W) imaging has been reported in chronic infratentorial superficial siderosis (SS), but its relationship to posterior fossa subarachnoid hemorrhagic change (PF-SAHC) remains unclear.PurposeTo evaluate the association of CM T1 signal with PF-SAHC grade and phase and its longitudinal changes.Material and MethodsThis r

Abstract

BackgroundCochlear modiolus (CM) T1 hyperintensity on thin-slice 3 T T1-weighted (T1W) imaging has been reported in chronic infratentorial superficial siderosis (SS), but its relationship to posterior fossa subarachnoid hemorrhagic change (PF-SAHC) remains unclear.PurposeTo evaluate the association of CM T1 signal with PF-SAHC grade and phase and its longitudinal changes.Material and MethodsThis retrospective study included 104 patients with subarachnoid hemorrhage or SS who underwent thin-slice (0.7 mm) 3 T T1W imaging between 2017 and 2025. CM T1 signal was assessed using a summed bilateral visual score (CM T1 score; range 0-4). CM T1 hyperintensity was defined as a score of 2 in either CM. PF-SAHC was graded as absent, focal, or diffuse (G0-G2) and classified as absent, acute-to-subacute, or chronic (P0-P2).ResultsCM T1 scores ≥ 2 were observed in 3.8% of G0, 51.2% of G1, and 100% of G2 patients, whereas scores of 3 or 4 were observed in 0%, 20.9%, and 100%, respectively. Receiver operating characteristic (ROC) analysis yielded an area under the ROC curve of 0.831, with the highest Youden index at a CM T1 score ≥ 2. CM T1 hyperintensity was observed in both P1 and P2. Exploratory longitudinal analysis showed increases and decreases in CM T1 score despite largely stable PF-SAHC grades.ConclusionCM T1 signal on thin-slice 3 T T1WI is associated with PF-SAHC grade and phase and may provide complementary information about posterior fossa hemorrhagic exposure.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Cochlear modiolus T1 hyperintensity as an additional imaging marker of posterior fossa subarachnoid hemorrhage — Science Skim