Comparative efficacy of leukocyte removal by blood filters in autologous cell salvage.
Mark Alm, Natasha Bush, Alisa Maznytsya, Mary Dooley, Laura Dell'aiera, Stuart A McCluskey, Mark Vallelonga
Department of Perfusion Services, Peter Munk Cardiac Centre, University Health Network, Toronto, ON, Canada. · Division of Cardiovascular Perfusion, Medical University of South Carolina, Charleston, SC, USA.
Key points
From the paper's conclusion- This quality improvement project evaluated the leukocyte removal efficacy of three types of salvaged blood filters in autologous cell salvage.MethodsUsing a prospective observational cohort approach, we evaluated microaggregate, lipid-reducing, and leukocyte-reducing salvaged blood filters in adult patients undergoing surgery with autologous cell salvage.
Abstract
BackgroundAutotransfusion devices concentrate white blood cells (WBCs) within the washed product that may lead to undesirable clinical effects when reinfused to the patient. This quality improvement project evaluated the leukocyte removal efficacy of three types of salvaged blood filters in autologous cell salvage.MethodsUsing a prospective observational cohort approach, we evaluated microaggregate, lipid-reducing, and leukocyte-reducing salvaged blood filters in adult patients undergoing surgery with autologous cell salvage. Filters were evaluated one after another, with samples of processed autologous blood collected prior to filtration and again after 30 mL had passed through each type of filter to allow for direct comparison of each filter's effects on WBC concentrations.ResultsSalvaged blood samples were collected from 35 patients. Median pre-filtration WBC count was 9.8 [6.8-13.3] × 109/L, being reduced to 9.3 [6.6-12.6] × 109/L after microaggregate filtration (1.7 [-0.6-4.6]% removal), 0.8 [0.5-2.5] × 109/L after lipid filtration (89.7 [83.3-93.9]% removal), and 0.0 [0.0-0.0] × 109/L after leukocyte filtration (100 [100-100]% removal). The microaggregate filter achieved significantly less WBC reduction than both the leukocyte-reducing filter (p < 0.0001) and lipid-reducing filter (p < 0.0001). There was no significant difference observed between the leukocyte-reducing and lipid-reducing filters (p = 0.3124).ConclusionsLeukocyte- and lipid-reducing filters were effective at reducing WBCs from processed autologous blood by nearly 10-fold, while microaggregate filters were significantly less effective at removing leukocytes. Use of leukocyte- or lipid-reducing filters minimizes the number of activated WBCs reinfused to the patient during autologous cell salvage.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Isolation and in vitro culture of endothelial progenitor cell-like populations from leukoreduction filters.BMC biotechnology · 2026
- Use of a cell saver device for perioperative autotransfusion in 102 dogs and one cat.Veterinary surgery : VS · 2026
- Expanding the supply of human leukocytes for research by harvesting cell concentrates from Trima Accel tubing sets.Scientific reports · 2026
- Cell-Free and Concentrated Ascites Reinfusion Therapy for Refractory Ascites Following Pediatric Liver Transplantation.Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy · 2026
- Association of intraoperative cell salvage combined with standard allogeneic transfusion with hematological parameters and clinical outcomes in pediatric tracheoplasty: a non-randomized cohort study.Frontiers in pediatrics · 2026
- Effects of washing with different crystalloid solutions on the oxygen delivery capacity and membrane integrity of salvaged erythrocytes: a comparative study in a rat modelBMC Anesthesiology · 2026