Robotic Reproduction of Therapeutic Massage via Adaptive Admittance Control and Single-Expert Kinematic-Dynamic Modeling.

Kui Huang, Yuan Xu, WeiChao Guo, LeYi Du

Guangming Traditional Chinese Medicine Hospital Pudong New Area, Shanghai, China. · State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China.

Key points

From the paper's conclusion
  • These findings support the feasibility of the expert-to-robot representation and execution framework.

Abstract

ObjectiveThis study tested whether therapeutic massage techniques demonstrated by a single experienced practitioner can be encoded as structured kinematic-dynamic signatures and reproduced robotically under adaptive admittance control.MethodsSingle-expert manual demonstrations of four mechanically distinct techniques - beating, pressing, pushing, and vibrating - were synchronously recorded using optical motion capture and tri-axial force sensing. Each technique was acquired as a 30-s continuous trial; after predefined screening, one stable analysis segment was retained per technique (Beat 8 s, Press 20 s, Push 20 s, and Vibrate 5 s). The retained demonstrations were characterized by active Cartesian degrees of freedom, movement excursion and timing, loading direction, force amplitude, and dominant frequency. These descriptors were mapped to technique-specific nominal robot trajectories, while adaptive admittance generated contact-direction corrections during execution. Reproduction fidelity was summarized descriptively by DTW-aligned waveform correlation, mean-force bias, relative mean-force bias, peak-force error, and dominant-frequency difference.ResultsAfter DTW alignment, robotic executions preserved force waveform morphology with high descriptive similarity across techniques (Pearson r = 0.858-0.925; Spearman rho = 0.817-0.907). Descriptive error metrics identified two technique-dependent mismatch patterns. Press and Push retained the principal cyclic or loading morphology but showed marked mean-force bias (+8.25 N, +33.55% for Press; -23.38 N, -43.66% for Push). Beat and Vibrate showed smaller absolute mean-force offsets (+1.79 N and -1.54 N, respectively), although Beat still exhibited a relative mean-force bias of +21.39%. Beat and Vibrate also showed larger dominant-frequency differences (-1.25 and -1.80 Hz, respectively). Peak-force error remained within ±2.11% for all four techniques.ConclusionUnder controlled biomimetic-interface conditions, single-expert massage demonstrations could be encoded as interpretable kinematic-dynamic signatures and reproduced robotically with high temporal waveform similarity, although force-amplitude and rhythm reproduction remained technique dependent. These findings support the feasibility of the expert-to-robot representation and execution framework. Broader reproducibility and clinical relevance require validation with multiple practitioners, repeated trials, dedicated controller-performance experiments, and human participants.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Robotic Reproduction of Therapeutic Massage via Adaptive Admittance Control and Single-Expert Kinematic-Dynamic Modeling — Science Skim