A Comparison of Item Selection Methods and Parameter Estimation Approaches for Online Calibration in Computerized Adaptive Testing.
Levent Ertuna, Cees A W Glas, Burcu Atar
Sakarya University, Türkiye. · University of Twente, Enschede, The Netherlands.
Key points
From the paper's conclusion- This study compared three pretest item selection methods (maximum Fisher information [MFI], D-optimal value design, and Bayesian D-optimal design), two parameter estimation methods (a fixed-ability joint maximum likelihood procedure [JML-itpar] and one expectation-maximization cycle [OEM]), three levels of random calibration stage sample size (250, 500, and 1,000), and three levels of calibration
Abstract
Online calibration enables continuous replenishment of computerized adaptive testing (CAT) item banks by embedding new pretest items within operational test sessions. However, the relative performance of different calibration components and their interactions have not been fully examined in a unified framework. This study compared three pretest item selection methods (maximum Fisher information [MFI], D-optimal value design, and Bayesian D-optimal design), two parameter estimation methods (a fixed-ability joint maximum likelihood procedure [JML-itpar] and one expectation-maximization cycle [OEM]), three levels of random calibration stage sample size (250, 500, and 1,000), and three levels of calibration sample size per pretest item (250, 500, and 1,000) under the one-parameter logistic and two-parameter logistic item response theory models through a Monte Carlo simulation with 108 conditions and 100 replications per condition. The results revealed a trade-off among item selection methods: MFI yielded the most accurate difficulty parameter estimates, while D-optimal value design and Bayesian D-optimal design produced better discrimination parameter recovery. Bayesian D-optimal design offered the best balance between accuracy and calibration efficiency. For the first time in the standard online calibration context, JML-itpar was systematically evaluated and found to be a viable estimation method. JML-itpar paired with MFI produced lower discrimination parameter root mean squared error than OEM at calibration sample sizes of 500 and 1,000. OEM remained superior for the difficulty parameter. The calibration sample size per pretest item was the most influential factor, with substantial accuracy gains from 250 to 500 responses and diminishing returns beyond 500. The random calibration stage sample size had negligible effects. These findings provide practical guidance for selecting calibration components in operational CAT programs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-Time Protection of Person-Parameter Updating and Item Selection in Computerized Adaptive Testing Under Item Preknowledge Using Response-Time Evidence.Educational and psychological measurement · 2026
- Variable-length fully Bayesian adaptive testing and associated stopping criteria.Behavior research methods · 2026
- Homogeneity-Pursuit Calibration of Item Response Theory Models with Limited Samples and Sparse Response Data.Multivariate behavioral research · 2026
- Recovering Accuracy From Miscalibrated Item Banks: Scoring Error Is Fixable, Selection Error Is Not.Educational and psychological measurement · 2026
- Calibration and Design Considerations for Multidimensional Multistage TestingEducational Measurement: Issues and Practice · 2026
- projectCAT: A Shiny Application for Computerized Adaptive Testing with Sympson-Hetter Exposure Control, Content Balancing, and Item Selection Method Comparison.Applied psychological measurement · 2026