Real-Time Quantification of Hydrogen and Deuterium Using Laser-Induced Breakdown Spectroscopy (LIBS) in the Off-Gas of an Engineering-Scale Pumped Molten Salt Loop
Zechariah B. Kitzhaber, Daniel Orea, J. McFarlane, Kevin Robb, Hunter B. Andrews
Oak Ridge National Laboratory
Key points
From the paper's conclusion- This online monitoring campaign demonstrates advancement in the application of LIBS for online monitoring of off-gas in molten salt systems.
Abstract
Laser-induced breakdown spectroscopy (LIBS) is being considered for elemental analysis of radionuclides transported into the off-gas system of molten salt reactors. A mobile LIBS system was calibrated for gas-phase measurements of hydrogen (i.e., protium, denoted here as H) and deuterium (D) in argon (Ar). The system was then used to quantify the concentrations of H and D in the off-gas of an engineering-scale molten salt loop (∼200 kg salt) following the addition of H 2 or D 2 as a 4% blend in Ar. The limits of detection for H and D were determined to be 0.0013 and 0.0011 mol% (13 and 11 parts per million), respectively. This research was carried out at the U.S. Department of Energy’s Oak Ridge National Laboratory in the Facility to Alleviate Salt Technology Risks (FASTR) pumped salt loop. Previous molten salt LIBS research has predominantly been performed at the bench scale, thus this study represents a major stride toward deploying LIBS technology for monitoring the performance of molten salt reactors. During the FASTR testing, the LIBS system operated continuously for several days. This online monitoring campaign demonstrates advancement in the application of LIBS for online monitoring of off-gas in molten salt systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of the furnace-opening configuration on the LIBS approach for Sr quantification in NaCl-CaCl2 molten salts.Analytical methods : advancing methods and applications · 2026
- Nanosecond-LIBS-induced deuterium outgassing, diffusion, and surface modification in tungsten coatingsNuclear Fusion · 2026
- A Real-Time Ortho-hydrogen Diagnostic for a Liquid Hydrogen ModeratorJournal of Physics: Conference Series · 2026
- Multivariate calibration for on-line spectroscopic monitoring of nuclear process streams: a review from fuel reprocessing to fusion tritium plantsJournal of Radioanalytical and Nuclear Chemistry · 2026
- Helium Detection in Technical MaterialsarXiv · 2026
- Laser-induced breakdown spectroscopy: an efficient analytical technique for qualitative and quantitative analysis [Invited]Journal of the Optical Society of America B · 2026