From Localization to Navigation: Expanding the Role of Intraoperative Ultrasound in Robotic Surgery.
Edward M Clarke, Kontoku Shimokawa, Osamu Yoshino
Division of Hapatopancreatobiliary Surgery and Liver Transplantation, Austin Hospital, Austin Health, Melbourne, VIC, Australia. · Department of Surgery, Ballarat Base Hospital, Grampians Health, Ballarat, VIC, Australia.
Key points
From the paper's conclusion- We report the case of a 77-year-old man with recurrent subphrenic abscesses, in whom these challenges were resolved with a robotic approach using a miniature drop-in ultrasound probe (FUJIFILM L51 K).
Abstract
Recurrent subphrenic abscess from retained radiolucent gallstones is a difficult problem: the stones are often difficult to localize due to its radiolucency, the operative field is confined and distorted due to its inflammation, and dissection lies close to the heart, pleura, and kidney. We report the case of a 77-year-old man with recurrent subphrenic abscesses, in whom these challenges were resolved with a robotic approach using a miniature drop-in ultrasound probe (FUJIFILM L51 K). The probe confirmed that a trans-diaphragmatic abscess and its contained stone lay deeper than the dissection plane suggested, defined a safe plane for de-roofing within 1 cm of the right atrium and pleura, and directed dissection of a second posterior collection between the inferior vena cava, pleura, and right kidney. All stones were retrieved without complication. The patient was discharged on day 5 and remained well at 20 months. This case illustrates the expanding role of advanced real-time imaging technologies in enhancing safety and precision in modern minimally invasive surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cross-platform integration of robotic intraoperative ultrasound using system-agnostic drop-in probes: technical feasibility and workflow standardization.Journal of robotic surgery · 2026
- Ultrasound-Guided Percutaneous Placement of Indocyanine Green-Dyed Coils for Intraoperative Localization of Subpleural Lung Tumors.Cureus · 2026
- Robotic-assisted needle placement in CT-guided percutaneous ablation in the abdomen: the SaFE post-market studyLa radiologia medica · 2026
- Robotic bronchoscopy delivery of optical ultrasound imaging for transbronchial lung biopsy guidance.Frontiers in medical technology · 2026
- Assessing the Clinical Utility of Ultrasound in Plastic and Reconstructive Surgery: Diagnostic and Interventional Applications.Annals of plastic surgery · 2026
- A Wireless, Bioresorbable Postoperative Treatment System with Temperature Feedback, Photothermal, and Drug Combination TherapyAdvanced Materials · 2026