Flicker-Evoked Changes in Red Blood Cell Flow and Distribution in Human Retinal Capillaries.
Yifu Ding, David Dierickx, Andrew Metha, Phillip Bedggood
Department of Optometry and Vision Sciences, University of Melbourne, Parkville, Victoria, Australia.
Key points
From the paper's conclusion- Within the sampled post-stimulation window, the flicker-evoked retinal capillary flow response was characterized primarily by broadly distributed, approximately proportional scaling across segments, with no evidence of homogenization. Some segments consistently lacked measurable flow, and their physiological role remains unclear.
Abstract
PURPOSE: To quantify flicker-induced changes in capillary flow and red blood cell (RBC) distribution in the human retina. METHODS: Capillary blood flow in the parafoveal region of five healthy subjects was imaged using high-speed flood-illumination adaptive optics at 300 fps. Measurements were obtained before and after 30 seconds of 10-Hz flicker stimulation (≥5 repeats). Changes in capillary diameter, RBC velocity, hematocrit, and transit time were quantified. RESULTS: Flicker stimulation increased mean RBC velocity by 11% (P < 0.001) but reduced pulsatility by 7.1% (P < 0.001). Mean capillary diameter increased by 3.5% (P < 0.01). Average transit time for individual capillary segments was reduced by 10.0% (P < 0.001), as was the standard deviation (SD) across segments (12.5%; P < 0.001), such that the coefficient of variation (CV) was preserved (P > 0.05). Average RBC flow increased (21.6%; P < 0.001), as did SD across segments (17.1%; P < 0.05), with no significant change in CV (P > 0.05). Despite variability in capillary diameter and RBC flow responses, no clear baseline-dependent relationship was observed for either parameter, and fractional RBC flow distribution at branches was preserved (P > 0.05). A subset of segments lacked RBC perfusion at both baseline and following stimulation. CONCLUSIONS: Within the sampled post-stimulation window, the flicker-evoked retinal capillary flow response was characterized primarily by broadly distributed, approximately proportional scaling across segments, with no evidence of homogenization. Some segments consistently lacked measurable flow, and their physiological role remains unclear.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of pharmacologic mydriasis on blood flow across different retinal regions measured by laser speckle contrast imaging in healthy adults.Microvascular research · 2026
- A Computational Pipeline for Retinal Capillary Blood Flow Measurement using Adaptive Optics Line Confocal Ophthalmoscopy.bioRxiv : the preprint server for biology · 2026
- EXPRESS: Visual gamma stimulation causes prolonged enhancement of low-frequency blood flow oscillations across superficial cortical regions in mice.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2026
- Robust High-Throughput Flickering Spectroscopy for Measurements of Red Blood Cell Membrane MechanicsbioRxiv · 2026
- Intraday and Interday Repeatability of Laser Speckle Contrast Imaging for Ocular Blood Flow Measurement in Healthy Subjects.Translational vision science & technology · 2026
- Interscan time influence on effective in-vivo choriocapillaris imaging using a scanning distortion-corrected high-speed OCT system.Biomedical optics express · 2026