Subspace-based reconstruction of k-t undersampled laminar fMRI in humans at 7T.
Yuhui Chai, Rong Guo, Rüdiger Stirnberg, Philipp Ehses, Tony Stöcker, Zhi-Pei Liang, Bradley P Sutton
Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, United States. · German Center for Neurodegenerative Diseases, Bonn, Germany.
Key points
From the paper's conclusion- Here, we tested whether spatiotemporally varying (k-t) undersampling combined with subspace-based reconstruction could address these constraints while preserving biologically meaningful laminar functional signatures in human fMRI at 7T.
Abstract
Laminar functional magnetic resonance imaging (fMRI) places stringent demands on image acquisition, as high spatial resolution (e.g., 0.6 mm), broad brain coverage, and efficient temporal sampling are difficult to achieve simultaneously. Here, we tested whether spatiotemporally varying (k-t) undersampling combined with subspace-based reconstruction could address these constraints while preserving biologically meaningful laminar functional signatures in human fMRI at 7T. We incorporated time-varying undersampling into segmented skipped-CAIPI 3D-EPI and combined it with a laminar-specific contrast, magnetization-transfer-enhanced blood-volume-and-perfusion-weighted imaging (MT-VAPER). Data were reconstructed using a low-rank subspace framework and applied at 0.6-mm resolution with 122-slice coverage and a net acceleration factor of 18.5. Performance was evaluated using temporal signal-to-noise ratio (TSNR), functional spatial blurring, preservation of canonical laminar response patterns in primary motor (M1) and visual cortex (V1), and task-signal leakage outside the expected activation regions. Subspace-based reconstruction substantially improved TSNR relative to standard reconstruction, while revealing fundamental parameter trade-offs: stronger regularization increased temporal stability at the cost of spatial specificity, whereas higher subspace rank reduced functional blurring but lowered TSNR. Under balanced reconstruction settings, key laminar signatures remained robust, including double-layer responses in M1 during finger tapping and middle-layer responses in V1 during checkerboard stimulation. Analysis of task-related signal leakage further showed that lower subspace ranks promoted global propagation of task-related signals into non-task brain regions and even outside the brain, whereas stronger regularization primarily produced local spatial smoothing without detectable global signal leakage. These results demonstrate that laminar-specific functional organization can be preserved under strong k-t undersampling while providing practical guidance for selecting subspace reconstruction parameters to balance temporal stability, spatial specificity, and reconstruction-induced signal leakage in human laminar fMRI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimising 7T-fMRI for Imaging Regions of Magnetic Susceptibility.Human brain mapping · 2026
- PISCO: Self-supervised k-space regularization for improved neural implicit k-space representations of dynamic MRIMedical Image Analysis · 2025
- Unsupervised Dynamic MRI Reconstruction via Low-Rank Patch-Based Tensor Functions with Implicit Neural Representation.IEEE journal of biomedical and health informatics · 2026
- Leveraging high-performance head-only gradients to enable ~2-fold higher multiband acceleration in SMS-EPI and SMS-EPTIarXiv · 2026
- Self-supervised reconstruction framework via motion- and physics-informed learning for four-dimensional magnetic resonance fingerprinting.Medical image analysis · 2026
- Hankel Subspace Self-Supervised Learning for Parallel MRI ReconstructionarXiv · 2026