Assessing the reliability of hippocampal single-voxel proton magnetic resonance spectroscopy through intra-class effect decomposition.
Martin Nilsson, Jonathan Berrebi, Sahar Nikkhou-Aski, Bárbara Avelar-Pereira, Per Thorsell, Vlad Legendi, Marc Guitart-Masip, Goran Papenberg
Aging Research Center, Department of Neurobiology, Care Sciences, and Society, Karolinska Institutet and Stockholm University, Sweden. · Stockholm University Brain Imaging Centre, Stockholm University, Stockholm, Sweden.
Key points
From the paper's conclusion- We assessed hippocampal metabolite estimates acquired with single-voxel MRS using a semi-adiabatic localization by adiabatic selective refocusing (semi-LASER) sequence at 3 T.
Abstract
The hippocampus is crucial for learning, memory, and stress regulation, but is vulnerable to influences that compromise its structural and metabolic integrity. Proton magnetic resonance spectroscopy (MRS) enables in vivo quantification of hippocampal neurochemistry, yet the absolute and relative reliability of these measures has rarely been systematically evaluated. We assessed hippocampal metabolite estimates acquired with single-voxel MRS using a semi-adiabatic localization by adiabatic selective refocusing (semi-LASER) sequence at 3 T. Nineteen healthy adults (8 male; mean age = 40.9 ± 16.9 years) underwent four measurements across 2 consecutive days, with one session including an extended acquisition. Absolute reliability was quantified using within-subject coefficients of variation (CVs), and relative reliability was estimated with the Intra-Class Effect Decomposition (ICED) framework, which partitions variance into true-score, day-specific, session-specific, and residual components. Despite good spectral quality and high absolute reliability for several metabolites, relative reliability ranged from poor to good. Good relative reliability was observed only for water-referenced myo-inositol, total choline, and total creatine; no creatine-referenced metabolite reached this threshold. Increasing the number of transients increased signal-to-noise ratio but did not improve relative reliability; only creatine-referenced total N-acetylaspartate showed significant session-specific variance. Thus, high absolute reliability did not necessarily imply high relative reliability. Hippocampal MRS at 3 T may, therefore, be suitable for group-level or mean-level metabolite estimates, but appears less suitable for correlational, biomarker, or other individual-difference applications that require stable between-person differences. Methodological refinement, including improved voxel placement, motion correction, shimming, and quantification pipelines, may improve the relative reliability of hippocampal MRS.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Testing the reliability of novel Voxel Placement approaches for Magnetic Resonance SpectroscopybioRxiv · 2026
- Regional cingulate metabolite-ratio differences exceed longitudinal changes across an approximately 34-h protocol: a prospective quality-controlled proton magnetic resonance spectroscopy study.Frontiers in medicine · 2026
- 1H-MR Spectroscopy as a Decision-Support Tool in the Differential Diagnosis of Intracranial Lesions: A Real-World Bicentric Retrospective Cohort.Diagnostics (Basel, Switzerland) · 2026
- A systematic approach to MR spectroscopy of the brain: Indications, protocol, metabolites, and spectral analysis in neurologic diseases.The neuroradiology journal · 2026
- Effect of Water Suppression and Metabolite Cycling on Quantification of ¹ H MRS Spectra in the Human Brain at 3 TeslaMagnetic Resonance in Medicine · 2026
- Accelerated Major Singlet Metabolite Mapping in Human Brain Using Nonwater/Fat‐Suppressed Ultrashort‐TR FID‐MRSI With FID‐Encoded IDEALNMR in Biomedicine · 2026