Standardized Ultrafast Transcranial Ultrasound Acquisition in Acute Stroke: The HYPER-AI-SCAN Pilot Study With Exploratory Artificial Intelligence Analysis.
Renato Simonetti, Jesús David González Riveros, Pere Canals, Manuel Alanís-Bernal, Julia Fernandez Martinez, Laia Boada Oller, Olalla Pancorbo, Noelia Rodriguez-Villatoro,
School of Medicine and Health Sciences Universitat Autònoma de Barcelona (UAB) Barcelona Spain. · Stroke Research Group Vall d'Hebron Research Institute (VHIR) Barcelona Spain.
Key points
From the paper's conclusion- Standardized ultrafast transcranial ultrasound acquisition was feasible at the bedside in acute stroke and generated brief cine-loops suitable for exploratory AI development. Multicenter external validation is required before diagnostic or triage application.
Abstract
BACKGROUND: Intracerebral hemorrhage requires rapid mechanism-specific treatment, yet early stroke triage relies on clinical severity scales that do not reliably distinguish hemorrhage from ischemic stroke. We assessed the feasibility of a standardized ultrafast transcranial ultrasound protocol designed to support subsequent artificial intelligence (AI)-based intracerebral hemorrhage detection. METHODS: HYPER-AI-SCAN (Hyper-Acute AI-Assisted Sonographic Cerebral Hemorrhage Assessment Network) was a single-center prospective feasibility study with embedded exploratory AI analysis. Between March and December 2025, 102 adults with acute computed tomography (CT)-confirmed stroke were prospectively enrolled according to trained operator availability. Primary feasibility outcomes were protocol completion, operator-rated adequate transtemporal windows, and acquisition time. In patients with retrievable paired baseline CT, exploratory AI analyses compared CT-only, ultrasound-only, and cross-modal CT-guided ultrasound models using patient-level area under the receiver operating characteristic curve, sensitivity, and specificity. RESULTS: Two patients were excluded after acquisition because insonation depth was <19 cm, yielding 100 evaluable patients (33 intracerebral hemorrhage; 67 ischemic stroke). The protocol was completed in all evaluable patients; adequate transtemporal windows were identified in 87%, and median acquisition time was 22 seconds (interquartile range, 13-31). Paired baseline CT images were available in 91 patients. Mean area under the receiver operating characteristic curve was 0.86 (SD, 0.07) for the CT-only model, 0.85 (SD, 0.14) for the ultrasound-only model, and 0.92 (SD, 0.07) for the cross-modal model. CONCLUSIONS: Standardized ultrafast transcranial ultrasound acquisition was feasible at the bedside in acute stroke and generated brief cine-loops suitable for exploratory AI development. Multicenter external validation is required before diagnostic or triage application. REGISTRATION INFORMATION: Clinicaltrials.gov. Identifier: NCT07319013.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Unveiling diagnostic variability: clinical performance and pitfalls of two commercial AI tools for intracranial haemorrhage detectionBMC Medical Informatics and Decision Making · 2026
- Artificial intelligence in acute stroke imaging: A comprehensive survey from imaging assessment to outcome prediction.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2026
- Ultrafast brain MRI at 3 T for suspected acute ischemic stroke: interchangeability of the ultrafast and standard protocols.Japanese journal of radiology · 2026
- Timeliness of Emergency Care for Intracerebral Hemorrhage Compared With Acute Ischemic Stroke.JAMA network open · 2026
- Automated pupillometry findings in intracerebral hemorrhage compared with acute ischemic stroke among patients with suspected emergent large vessel occlusion.Clinical neurology and neurosurgery · 2026
- Development and validation of an automated MRI-based pipeline for temporal classification of intracerebral hemorrhage using U-Net segmentation and machine learning.Radiological physics and technology · 2026