Journal of the American Heart Association

Institutional Variation in Electroencephalography Utilization in Neonates With Complex Congenital Heart Disease Across the United States and Its Association With Outcomes.

Safwat Aly, Mohamed F Elsisy, Ibrahim Qattea, Jane W Newburger, Hany Z Aly

Department of Cardiology Boston Children's Hospital Boston MA USA. · Division of Pediatric Cardiology, Department of Pediatrics, Monroe Carell Jr. Children's Hospital at Vanderbilt Vanderbilt University Medical Center Nashville TN USA.

Observational · n=13,202

Key points

From the paper's conclusion
  • EEG utilization in neonates with complex congenital heart disease is increasing but remains low and highly variable across US centers. The association of EEG use with higher mortality and costs may reflect confounding by indication or illness severity. Standardized protocols are needed to optimize neurologic monitoring and improve long-term outcomes.

Abstract

BACKGROUND: Neonates with complex congenital heart disease are at increased risk for perioperative brain injury and seizures. Electroencephalography (EEG) detects clinical and subclinical seizures, but national utilization patterns remain poorly characterized. METHODS: We conducted a retrospective cohort study using the Pediatric Health Information System (2016-2025) of neonates ≤28 days with dextro-transposition of the great arteries or single-ventricle physiology undergoing surgical repair or palliation. Mixed-effects logistic regression with hospital as a random effect identified predictors of EEG utilization. RESULTS: Among 13 202 neonates, 1654 (12.5%) underwent EEG monitoring. EEG monitoring was performed in only 10.8% of neonates with dextro-transposition of the great arteries, 16% of those with hypoplastic left heart syndrome, and 13% of those with non- hypoplastic left heart syndrome single-ventricle lesions. EEG utilization increased from ~6% in 2016 to >14% in 2025, while seizure detection among EEG-monitored patients increased from 13% to ~26% (both P-trend<0.01). Utilization varied substantially across hospitals (0% to >40%), persisting after adjustment for surgical volume. EEG-monitored neonates had higher seizure detection (21.8% versus 5.2%), longer length of stay (33 versus 24 days), and higher hospitalization costs ($344 719 versus $174 865; all P<0.01). In multivariable analysis, EEG utilization was independently associated with seizures (OR ~4), dextro-transposition of the great arteries, and hypoplastic left heart syndrome, but not with cardiac arrest, extracorporeal membrane oxygenation, or hypoxic-ischemic encephalopathy. CONCLUSIONS: EEG utilization in neonates with complex congenital heart disease is increasing but remains low and highly variable across US centers. The association of EEG use with higher mortality and costs may reflect confounding by indication or illness severity. Standardized protocols are needed to optimize neurologic monitoring and improve long-term outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Institutional Variation in Electroencephalography Utilization in Neonates With Complex Congenital Heart Disease Across the United States and Its Association With Outcomes — Science Skim