Journal of the American Heart Association

Cardiac Myosin-Binding Protein C for Diagnosis of Myocardial Infarction in Patients With Prior Coronary Artery Bypass Grafting.

Rebekka Odermatt, Luca Koechlin, Pedro Lopez-Ayala, Emel Kaplan, Lourdes Herraiz Recuenco, Gabrielle Huré, Paolo Bima, Luca Crisanti,

Cardiovascular Research Institute Basel and Department of Cardiology University Hospital Basel, University of Basel Basel Switzerland. · Department of Cardiac Surgery University Hospital Zurich, University of Zurich Zurich Switzerland.

Trial · n=4,752

Key points

From the paper's conclusion
  • In patients with prior CABG, cMyC demonstrated high diagnostic accuracy for myocardial infarction, but not superior to established hs-cTnT and hs-cTnI assays.

Abstract

BACKGROUND: Diagnosing myocardial infarction in patients with prior coronary artery bypass grafting (CABG) remains challenging, primarily because of lower diagnostic accuracy of high-sensitivity cardiac troponin (hs-cTn). cMyC (cardiac myosin-binding protein C), because of its faster release kinetics and greater abundance, may offer improved diagnostic performance in this population. METHODS: The diagnostic accuracy of cMyC was directly compared with that of hs-cTnT and hs-cTnI in a prospective, international, multicenter, diagnostic study enrolling adult patients presenting to the emergency department with acute chest discomfort. Final diagnoses were centrally adjudicated by 2 independent cardiologists using all available clinical and study-specific data, including imaging and serial hs-cTnT measurements. Patients were stratified according to the presence or absence of prior CABG. RESULTS: Among 4752 patients, 387 (8%) had prior CABG (median age, 75 years; 86% men). The incidence of myocardial infarction was significantly higher in patients with prior CABG (38% versus 16%; P<0.001). In the CABG group, the diagnostic accuracy of cMyC as quantified by the area under the curve was 0.88 (95% CI, 0.85-0.92), which was comparable but not superior to that of hs-cTnT (0.89 [95% CI, 0.86-0.92]) and hs-cTnI (0.88 [95% CI, 0.84-0.91]). These findings were consistent across alternative high-sensitivity cMyC assays. CONCLUSIONS: In patients with prior CABG, cMyC demonstrated high diagnostic accuracy for myocardial infarction, but not superior to established hs-cTnT and hs-cTnI assays. REGISTRATION: URL: clinicaltrials.gov; Unique Identifier: NCT00470587.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers