PASCAL Precision System Outcomes by Implant Location and Lesion Location in Degenerative Mitral Regurgitation Patients From the STS/ACC TVT Registry.
P Kasi Ramanathan, Raj Makkar, Thomas Waggoner, Azeem Latib, Robert M Kipperman, Ivan Hanson, Anjan K Sinha, Tarun Chakravarty,
Promedica Toledo Hospital Toledo OH USA. · Cedars-Sinai Medical Center Los Angeles CA USA.
Key points
From the paper's conclusion- In real-world patients with degenerative mitral regurgitation, treatment with the PASCAL Precision system was associated with favorable safety and effectiveness at 30 days, regardless of implant location or leaflet lesion location.
Abstract
BACKGROUND: Mitral valve transcatheter edge-to-edge repair can be more challenging in noncentral regions of the valve and in anterior or bileaflet lesions. We assess effect of implant location and leaflet lesion location on safety and effectiveness of PASCAL Precision system in degenerative mitral regurgitation (MR). METHODS: Mitral valve transcatheter edge-to-edge repair outcomes in patients with degenerative MR treated with PASCAL Precision system (September 2022-October 2024), from the US STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry, were analyzed by implant location (A2P2/non-A2P2) and leaflet lesion location (anterior/posterior/bileaflet). Procedural, clinical, and echocardiographic outcomes to 30 days were assessed. RESULTS: At 30 days, both A2P2 (n=1526) and non-A2P2 (n=299) groups had low event rates (cardiovascular mortality: 1.1% versus 1.0%, mitral valve reintervention: 0.4% versus 0.0% and single leaflet device attachment: 0.5% versus 0.3%; all P>0.05) and demonstrated significant MR reduction (P<0.001 versus baseline) with no significant difference between groups (P=0.750) (MR ≤2+: 93.4% versus 95.4%; MR ≤1+: 72.0% versus 73.3%). Kansas City Cardiomyopathy Questionnaire Overall Summary scores improved significantly in both groups (∆19.3, ∆17.7 points; P=0.741). The anterior (n=250), posterior (n=902), and bileaflet (n=192) disease groups also had low event rates (cardiovascular mortality: 0.4%, 1.1%, 0.0%; mitral valve reintervention: 0.8%, 0.1%, 0.5%; and single leaflet device attachment: 0.8%, 0.2%, 0.5%; all P>0.05), and demonstrated significant MR reduction (P<0.001 versus baseline) with no significant difference across groups (P=0.459) (MR ≤2+: 94.1%, 93.1%, and 94.5%; MR ≤1+: 79.0%, 69.2%, and 72.4%). All groups experienced significant improvement in Kansas City Cardiomyopathy Questionnaire Overall Summary scores (∆21.4, ∆18.8, ∆12.0 points; P=0.087). CONCLUSION: In real-world patients with degenerative mitral regurgitation, treatment with the PASCAL Precision system was associated with favorable safety and effectiveness at 30 days, regardless of implant location or leaflet lesion location.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Three-dimensional mitral valve geometry after transcatheter edge-to-edge repair: PASCAL versus PASCAL-ACE-implications for devices selection.Clinical research in cardiology : official journal of the German Cardiac Society · 2026
- Challenging the limits of mitral-TEER: a PASCAL case in the anatomical 'red zone': a case report.European heart journal. Case reports · 2026
- Transcatheter Edge-to-Edge Repair With MitraClip G4 System Compared With PASCAL System in Patients With Functional Mitral Regurgitation: A Propensity Score-Matched Analysis.Journal of the American Heart Association · 2026
- Transcatheter Edge-to-Edge Repair With the PASCAL Precision System: Advanced Catheter Steering Maneuvers for Mitral and Tricuspid Interventions.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- One-Year Outcomes of M-TEER With the PASCAL System in Atrial and Ventricular FMR: Insights From the MiCLASP Postmarket Clinical Follow-Up Study.Circulation. Cardiovascular interventions · 2026
- A Pascal in ring: Transcatheter edge-to-edge tricuspid repair for severe regurgitation within a surgical annuloplasty ring.Annales de cardiologie et d'angeiologie · 2026