Journal of the American Heart Association

Efficacy and Safety of Jailed Balloon-Proximal Optimization Technique Versus Jailed Wire Technique for Preventing Side Branch Occlusion During Percutaneous Coronary Intervention of True Non-Left Main Bifurcation Lesions: A Multicenter, Open-Label, Randomized Controlled Trial.

Chuncheng Gao, Huimiao Dai, Jing Han, Dongdong Li, Xuan Lu, Hao Liu, Haotian Zhe, Pengyun Liu,

Department of Cardiology Tangdu Hospital, The Fourth Military Medical University Xi'an Shaanxi China. · Department of Cardiology The Second Hospital of Weinan Weinan Shaanxi China.

Randomised · n=110

Key points

From the paper's conclusion
  • JB-POT significantly reduced SB occlusion, procedure time, and contrast volume versus JWT in non-left main bifurcation percutaneous coronary intervention, with comparable periprocedural safety. It represents a novel SB protection strategy, particularly beneficial in acute myocardial infarction, renal dysfunction, or consecutive bifurcation lesions.

Abstract

BACKGROUND: The jailed balloon technique prevents side branch (SB) occlusion during coronary bifurcation stenting but is complex. We developed a jailed balloon-proximal optimization technique (JB-POT) to simplify jailed balloon technique and compared its efficacy and safety with conventional jailed wire technique (JWT) for non-left main bifurcation lesions. METHODS: In this multicenter randomized controlled trial, 110 patients with true non-left main bifurcation lesions (Medina 1,0,1; 1,1,1; 0,1,1) were randomized to JB-POT (N=55) or JWT (N=55). The primary end point was SB occlusion rate after main vessel stenting/proximal optimization technique. Secondary end points included stent malapposition, target lesion failure (composite of cardiovascular death, target vessel myocardial infarction, and revascularization), stent thrombosis, procedure time, and contrast volume. RESULTS: JB-POT significantly reduced SB occlusion (1.8% versus 20%; P=0.006), shortened procedure time (67 [53-85] versus 82 [62-99] minutes; P=0.009), and lowered contrast volume (140 [120-160] versus 160 [130-190] mL; P=0.002) versus JWT. Severe stent malapposition occurred in 5.5% (JB-POT) versus 0% (JWT) (P=0.242). Perioperative target lesion failure (P=0.475) and stent thrombosis (P=0.242) were comparable, but JB-POT showed a tendency for improved 12-month target lesion failure-free survival (P=0.023) and a nonsignificant trend toward reduced stent thrombosis (P=0.079). Multivariable analysis identified diabetes (odds ratio [OR], 7.26), SB ostial stenosis (OR, 1.09), balloon number (OR, 1.96), and diastolic blood pressure (OR, 1.07) as exploratory SB occlusion associates. CONCLUSIONS: JB-POT significantly reduced SB occlusion, procedure time, and contrast volume versus JWT in non-left main bifurcation percutaneous coronary intervention, with comparable periprocedural safety. It represents a novel SB protection strategy, particularly beneficial in acute myocardial infarction, renal dysfunction, or consecutive bifurcation lesions. REGISTRATION: URL: https://www.chictr.org.cn; Unique Identifier: ChiCTR2300071356.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers