Interobserver Variability in Pulmonary Cytopathology Diagnostics by Whole-slide Digital Cytology-A multi-expert International Study.
Hatice Elmas, Binnur Önal, Ivana Kholová, Fernando Schmitt, Ilkser Akpolat, Seyma Büyücek, Levent Trabzonlu, Jamal Musayev,
Key points
From the paper's conclusion- WSI enables international collaboration and remote review of pulmonary cytology, but substantial variability persists in observer interpretations. WSI is currently feasible mainly for consultation, education, and quality assurance, but it is not yet equivalent to conventional microscopy for primary diagnostics, underlining the need for workflow optimization, cytology‑specific validation, and structured digital training.
Abstract
BACKGROUND: Digital imaging in cytopathology is transforming information exchange and remote diagnostics. Internet-based platforms and algorithms are increasingly expected to support cyto‑ and histopathological reporting workflows. This study evaluated interobserver concordance, diagnostic accuracy, causes of misdiagnosis, scanning time, and review time among ten expert cytologists using whole slide imaging (WSI). The primary aim was to identify challenges in applying WSI to cytopathology and to propose strategies to address them. METHODS: This retrospective study included 61 intraoperative pulmonary cytology samples (30 women, 31 men; mean age 66.1 years) from the LungenClinic Grosshansdorf acquired between January 2020 and December 2021. A total of 61 Giemsa‑stained preparations (54 imprint/touch preparations, five fine‑needle aspirates, and two sediment smears of pleural effusions) were scanned using a Leica Aperio AT2 scanner and uploaded to an internet platform. Histology served as the reference standard and showed 19 benign and 42 malignant lesions. RESULTS: Sixty‑one cytological cases (19 benign, 42 malignant) were assessed by ten observers. Interobserver agreement for categorical diagnoses was slight (Fleiss' kappa = 0.099), whereas ranking concordance was moderate (Kendall's tau = 0.314). Evaluation times ranged from 20 to 667.8 seconds per case, indicating substantial variability in digital navigation speed. CONCLUSIONS: WSI enables international collaboration and remote review of pulmonary cytology, but substantial variability persists in observer interpretations. WSI is currently feasible mainly for consultation, education, and quality assurance, but it is not yet equivalent to conventional microscopy for primary diagnostics, underlining the need for workflow optimization, cytology‑specific validation, and structured digital training.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Interobserver Variability and Cytotechnologist Performance in Digital Cervical Cytology: An International European Federation of Cytological Societies StudyCytopathology · 2026
- Diagnostic concordance of remote WSI-based thyroid cytology compared to conventional cytological diagnosis: a pilot study.Diagnostic pathology · 2026
- Cytopathology 2.0: How Artificial Intelligence Is Redefining the Future of Cytopathology.Journal of cytology · 2026
- Diagnosis of infectious disease pathology on whole slide images: a multi-platform evaluation with implications for digital laboratory practice.Histopathology · 2026
- Interobserver variability in the interpretation of Papanicolaou tests using the Hologic Genius Digital Diagnostics System: detailed analysis of cytology verification in a large academic laboratory.American journal of clinical pathology · 2026
- The Role of Whole Slide Imaging in AI-Based Digital Pathology: Current Challenges and Future Directions—An Updated Literature ReviewJournal of Molecular Pathology · 2026