Characterizing the Impact of Light Settings on Whiteout Frames during Flexible Endoscopic Evaluation of Swallowing.
Gayathri Karthikeyan, Jessica M Pisegna
Boston University School of Public Health, Boston University, Boston, USA. · Department of Speech-Language Pathology, Boston Medical Center, Boston, USA, jpisegna@gmail.com.
Key points
From the paper's conclusion- These preliminary findings suggest that endoscopic light settings may influence the appearance, and measured frame counts of whiteout and pinkout during FEES. Automatic and manual light settings produced different patterns of pure whiteout and pinkout frames, while combined whiteout + pinkout frame counts were more similar across settings. These findings support the importance of documenting and, when possible, standardizing light and brightness settings in FEES research and clinical reporting.
Abstract
INTRODUCTION: This study sought to assess whether an endoscope's light setting influenced the number of flexible endoscopic evaluation of swallowing (FEES) whiteout or pinkout frames in healthy subjects. We hypothesized that the number of whiteout frames during swallows from healthy participants would differ depending on the manual or automatic light setting. METHODS: Data were collected to assess the effect of Olympus endoscope light settings during FEES from healthy participants. Following a protocol of standard boluses, the light source was alternated between automatic and manual settings. During each swallow, purely white frames ("whiteout") and other hue frames ("pinkout") were counted for each bolus and light setting. A linear mixed-effects model was used to compare automatic and manual light settings while accounting for repeated swallows within participants and adjusting for bolus type. RESULTS: Retrospective FEES videos from 8 healthy volunteers were used, and 117 swallows were analyzed. In descriptive analyses, the mean number of pure whiteout frames per swallow was 1.50 frames in the automatic setting and 13.97 frames in the manual setting. In the mixed-effects model, pure whiteout frame count was significantly lower in the automatic setting than in the manual setting (adjusted mean scores: 1.45 vs. 13.76 frames; p < 0.001). Pinkout frame count showed the opposite pattern and was significantly higher in the automatic setting than in the manual setting (adjusted mean scores: 14.42 vs. 3.26 frames; p < 0.001). When whiteout and pinkout frames were combined, there was no significant difference between automatic and manual light settings (adjusted mean scores: 16.17 vs. 16.84 frames; p = 0.681). A greater proportion of combined whiteout + pinkout frame counts fell within the expected normative whiteout-duration range under the automatic versus manual light setting (84.8% vs. 81.7%, respectively). CONCLUSION: These preliminary findings suggest that endoscopic light settings may influence the appearance and measured frame counts of whiteout and pinkout during FEES. Automatic and manual light settings produced different patterns of pure whiteout and pinkout frames, while combined whiteout + pinkout frame counts were more similar across settings. These findings support the importance of documenting and, when possible, standardizing light and brightness settings in FEES research and clinical reporting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Disparate Practice Patterns in Dysphagia Diagnostics With Flexible Endoscopic Evaluation of Swallowing: An Exploratory Study.American journal of speech-language pathology · 2026
- Practice Variation in Flexible Endoscopic Evaluation of Swallowing (FEES): An International Survey.Dysphagia · 2026
- Reliability of a High-Speed Videoendoscopy Protocol for Swallowing Analysis.The Laryngoscope · 2026
- Deep learning-based pediatric swallowing video segmentation from sparse multi-annotator endoscopic data: comparing supervised U-Net models and in-context segmentation.Medical & biological engineering & computing · 2026
- LUCID: Intelligent Informative Frame Selection in Otoscopy for Enhanced Diagnostic Utility.Diagnostics (Basel, Switzerland) · 2026
- Impact of reduced frame rate on kinematic analyses in videofluoroscopic swallowing studiesJournal of Exercise Therapy and Rehabilitation · 2026