Systematic Differences Between Ultrasound and Magnetic Resonance Imaging Assessment of Fetal Ventricular Width in Cases of Fetal Mild Ventriculomegaly: A Cohort Study.
Boyana Mikulska, Renata Jaczyńska, Paulina Sobieraj-Bińkiewicz, Magda Rybak-Krzyszkowska, Tomasz Maciejewski, Monika Bekiesińska-Figatowska
Department of Obstetrics and Gynecology, Institute of Mother and Child Warsaw, Poland. · Department of Diagnostic Imaging, Institute of Mother and Child Warsaw, Poland.
Key points
From the paper's conclusion- These systematic differences may change the VM classification and should be considered in clinical interpretation.
Abstract
INTRODUCTION: Prenatal assessment of the lateral ventricles is essential for detecting and classifying fetal ventriculomegaly (VM). Although ultrasound (US) is the primary screening tool, magnetic resonance imaging (MRI) is increasingly used to complement diagnosis. However, discrepancies between US and MRI measurements, particularly in mild VM, may affect classification, counseling, and planning clinical management. The aim of the study was to compare US and MRI measurements of the fetal lateral ventricles, evaluate the agreement between both methods, with particular focus on mild ventriculomegaly, and additionally assess the feasibility of deriving conversion formulas between both modalities. METHODS: This retrospective cohort study included 120 fetuses examined between 2011 and 2021 at a referral center: 75 with isolated mild VM and 45 controls. All underwent a standardized US assessment and fetal MRI. Ventricular width was measured twice for each modality; mean values were used for statistical comparison. Analysis included Wilcoxon tests, Friedman tests, Bland-Altman plots, Pearson's chi-square tests, Theil-Sen regression, and linear modeling. RESULTS: MRI systematically provided greater ventricular measurements than US. In the study group, the bias was 0.71 mm for coronal MRI and 0.33 mm for axial MRI. Agreement between methods was limited, with measurement discrepancies observed in 34% of cases (coronal) and 33.3% (axial). Combined analysis of both groups confirmed persistent measurement discrepancies, though the overall axial MRI bias decreased to 0.15 mm. Theil-Sen modeling enabled the development of conversion formulas for both measurement planes. DISCUSSION: MRI measurements of the fetal lateral ventricles tend to be slightly higher than US measurements, particularly in the coronal plane. These systematic differences may change the VM classification and should be considered in clinical interpretation. Ultrasound demonstrated better measurement reproducibility. The obtained formulas may support improved cross-modality comparison in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fetal Ventriculomegaly Across the Severity Spectrum: Prenatal Ultrasound Features, Longitudinal Evolution, and Additional Fetal MRI Findings.Diagnostics (Basel, Switzerland) · 2026
- Standard Prenatal Ultrasound Markers Associated With MRI ‐Only Central Nervous System Abnormalities in Fetal VentriculomegalyJournal of Clinical Ultrasound · 2026
- Mild Ventriculomegaly, Ventricular Asymmetry, and Posterior Fossa Variants: A Narrative Review of Borderline Fetal Brain Findings.Diagnostics (Basel, Switzerland) · 2026
- Biometric Assessment of Pathological Fetal Corpus Callosum: Ultrasound Versus MRI.Journal of clinical ultrasound : JCU · 2026
- Neonatal quantitative susceptibility mapping at 7 T: toward MRI markers of developmental myelination and brain ironFrontiers in Neuroscience · 2026
- Data quality biases normative models derived from fetal brain MRI.Imaging neuroscience (Cambridge, Mass.) · 2026