Fetal diagnosis and therapy

The Fetal Ear-Eye and Ear-Rotation Angle: A Pilot Study on Novel 3D Ultrasound Measurements for Prenatal Diagnosis of Low-Set Ears.

Thabea Katrin Musik, Sara Monteiro, Heidrun Schönberger, Annkathrin Butenschön, Cecile Monod, Jutta Benz, Andreas Schoetzau, Beatrice Mosimann,

Division of Gynecological Ultrasound and Prenatal Diagnosis, Department of Obstetrics and Gynecology, University Hospital Basel, Basel, Switzerland.

Key points

From the paper's conclusion
  • Systematic evaluation of the fetal ear on routinely collected 3D volumes is feasible. Both angles were significantly larger in affected fetuses compared to healthy controls. However, due to the limited sample size and prevalence of abnormal cases, these diagnostic performance metrics should be interpreted with caution and require validation in larger cohorts.

Abstract

INTRODUCTION: Low-set ears are frequently associated with chromosomal aberrations, congenital malformations, and genetic syndromes. While typically described postnatally, prenatal diagnosis usually relies on subjective expert pattern recognition. We introduce a standardized three-dimensional (3D) ultrasound measurement approach to assess fetal ear position relative to the eye and head. METHODS: Retrospective pilot analysis of prospectively acquired 3D head volumes (16-34 weeks; 10/2023-10/2025). The "ear-eye angle," "ear-rotation angle," and ear length were measured by 2 blinded examiners in healthy controls and a malformation group. RESULTS: We included 102 fetuses (82 controls, 20 malformations) at a median 21 weeks' gestation (16-34). The malformation group had a significantly larger median ear-eye angle than controls (3.29° [-2.81 to 7.88] versus 1.02° [-11.04 to 8.75]; p < 0.001) and median ear-rotation angle (17.50° [-33.75 to 37.20] versus 12.10° [0.00-38.40]; p = 0.029). Logistic regression showed that for every one-degree increase in the ear-eye angle, the odds of a malformation increased significantly (OR 1.36; 95% CI: 1.11-1.65; p = 0.002). Receiver operating characteristic analysis revealed the ear-eye angle had superior discriminative ability over the ear-rotation angle (area under the curve 0.76 versus 0.66). Inter-observer agreement was high (ear-eye intraclass correlation coefficient [ICC] = 0.96; ear-rotation ICC = 0.92). CONCLUSION: Systematic evaluation of the fetal ear on routinely collected 3D volumes is feasible. Both angles were significantly larger in affected fetuses compared to healthy controls. However, due to the limited sample size and prevalence of abnormal cases, these diagnostic performance metrics should be interpreted with caution and require validation in larger cohorts.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

The Fetal Ear-Eye and Ear-Rotation Angle: A Pilot Study on Novel 3D Ultrasound Measurements for Prenatal Diagnosis of Low-Set Ears — Science Skim