Digestion

Technical Advances in Immersion-Based Endoscopic Submucosal Dissection for Superficial Non-ampullary Duodenal Epithelial Tumors.

Osamu Dohi, Tomoki Uehara, Ryohei Obata, Junki Yumoto, Mayuko Seya, Katsuma Yamauchi, Mariko Kajiwara, Hiroaki Kitae,

Review

Key points

From the paper's conclusion
  • These technical advances of immersion-based ESD could be adopted as a less invasive treatment for appropriately selected patients with SNADETs.

Abstract

BACKGROUND: Duodenal endoscopic submucosal dissection (ESD) is still technically challenging and contributing to high rates of adverse events with conventional gas-insufflation ESD (C-ESD). Immersion-based ESD techniques have recently been developed to overcome these limitations and improve procedural safety. SUMMARY: Saline immersion ESD (SI-ESD), including underwater ESD, the water pressure method (WPM), and the saline-immersion/irrigation technique, provides improved scope maneuverability, enhanced visualization of the submucosal space, and a reduced risk of intraoperative perforation compared with conventional gas-insufflation ESD (C-ESD). However, blood readily diffuses into the surrounding saline during intraoperative bleeding, impairing visualization, and bubble formation, fluid turbulence, and aspiration risk remain limitations. Gel immersion ESD (GI-ESD), while sharing the low-pressure and buoyancy-related advantages of SI-ESD, employs an electrolyte-free viscous gel whose high viscosity suppresses blood diffusion, confining blood to the bleeding site and maintaining a clearer visual field during intraoperative bleeding. A retrospective comparative study demonstrated comparable en bloc and R0 resection rates between GI-ESD and C-ESD, with significantly lower muscle layer exposure and no perforation events in the GI-ESD group. Several immersion-based and adjunctive closure techniques have achieved high complete closure rates for post-ESD mucosal defects, reducing delayed adverse events. KEY MESSAGES: Immersion-based ESD reduces intraoperative perforation risk through low intraluminal pressure and improved scope maneuverability. GI-ESD offers additional safety advantages over SI-ESD, including a clearer visual field during bleeding. Immersion-based closure techniques further reduce delayed adverse events. These technical advances of immersion-based ESD could be adopted as a less invasive treatment for appropriately selected patients with SNADETs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers