Impact of RapidAI® Implementation on Workflow Metrics and Access to Reperfusion Therapies in Acute Ischemic Stroke: A 10-Year Retrospective Analysis.
Pablo Enrique González, Pablo M Lavados, Alejandro M Brunser, Víctor Hugo Navia, Matías Cristobal Niedbalski, Carolina Andrea Vargas, Veronica V Olavarria
Key points
From the paper's conclusion- RapidAI® implementation coincided with improved metrics in hospital length of stay and the need for decompressive craniectomy. Given low software utilization and potential secular trends, findings should be interpreted cautiously.
Abstract
BACKGROUND AND PURPOSE: Artificial intelligence‑assisted perfusion imaging can support selection and coordination in acute ischemic stroke (AIS). This study assessed institutional changes in access to reperfusion therapies and workflow metrics before and after RapidAI® implementation. METHODS: We retrospectively analyzed consecutive AIS admissions (July 2014-October 2024) at a single comprehensive stroke center, comparing pre‑implementation and post‑implementation periods (RapidAI® introduced June 2018). Primary outcomes were utilization of intravenous thrombolysis (IVT) and mechanical thrombectomy (MT), mRS 0-1 at discharge, and decompressive craniectomy (DC). Secondary outcomes were 90‑day mRS, door‑to‑needle (DTN) time, and hospital length of stay (LOS). Analyses were adjusted for key confounders and sensitivity analyses were made. RESULTS: Among 2,144 patients, adjusted analyses showed no significant differences in IVT (adjusted OR 0.93; 95% CI 0.52-1.69; p = 0.822) or MT (adjusted OR 2.73; 95% CI 0.70-10.61; p = 0.147) between periods. Rescue decompressive craniectomy was lower in the post period (adjusted OR 0.15; 95% CI 0.03-0.82; p = 0.029) and hospital length of stay was reduced (adjusted B -2.33 days; 95% CI -3.62 to -1.03; p < 0.001). No significant adjusted differences were observed for door to needle time (B -0.56 minutes; 95% CI -32.44 to 31.32; p = 0.972), discharge mRS 0-1 (adjusted OR 1.47; 95% CI 0.90-2.39; p = 0.126), discharge mRS ordinal (B -0.29; 95% CI -0.62 to 0.05; p = 0.091), or 90 day mRS ordinal (B -0.26; 95% CI -0.64 to 0.12; p = 0.174). Sensitivity analyses after multiple imputation produced consistent results. CONCLUSIONS: RapidAI® implementation coincided with improved metrics in hospital length of stay and the need for decompressive craniectomy. Given low software utilization and potential secular trends, findings should be interpreted cautiously.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial intelligence for the detection of large vessel occlusion stroke and workflow optimization: a systematic review and meta-analysis.Journal of neurosurgical sciences · 2026
- Implementation of an AI-supported decision-making tool in a high-volume stroke system with routine perfusion imaging.European stroke journal · 2026
- Artificial intelligence imaging decision support for acute stroke treatment in England: a prospective observational studyThe Lancet Digital Health · 2025
- AI-enhanced pathway reorganization in drip-and-ship stroke management: Italian MDRinAIS experienceEuropean Journal of Public Health · 2026
- RapidAI compared to RapidAI-assisted neuroradiologist interpretation in evaluating acute ischaemic stroke: A local experience.Clinical radiology · 2026
- Artificial intelligence-driven imaging-based prediction models for hemorrhagic transformation after mechanical thrombectomy in acute ischemic stroke: a systematic review and meta-analysis.Frontiers in neurology · 2026