Evaluation of a Fine Structure Sound-Coding Strategy for Acoustic Perception in New Cochlear Implant Users.
Gwenaelle Creff, Maxime Codet, Nicolas Bernard-Le Liboux, Vincent Pean, Myriam Le Coq, Hermine Bourdon, Benoit Godey
Department of Otolaryngology-Head and Neck Surgery, University Hospital, Rennes, France. · Research Department, MED-EL, Paris, France.
Key points
From the paper's conclusion- FS4 was associated with improved music perception and speech recognition in quiet compared to HDCIS in newly implanted cochlear implant users, suggesting potential advantages of fine structure processing strategies. N° West V Ethics Committee: 2016-A01952-49. December 28, 2016.
Abstract
INTRODUCTION: Sound can be divided into 2 forms of temporal information: envelope and fine structure. While cochlear implants (CIs) are effective in speech recognition in quiet, they are less effective for listening in noise and for music perception. This study aimed to compare a fine structure processing (FSP) strategy (FS4) with a previous coding strategy (HDCIS) in newly implanted CI users. METHODS: This prospective, randomized, cross-over, double-blind study included 19 participants between January 2017 and July 2018. Each participant was randomized to receive a map programmed with FS4 followed by a map programmed with HDCIS or vice versa. Tonal/vocal audiometry in quiet, music perception tests (Gabrielsson scale, interval test, melodic contour identification [MCI]), and quality of life (Hearing Implant Sound Quality Index [HISQUI]) assessments were conducted after 1 month of adaptation to each setting. RESULTS: FS4 significantly improved speech recognition in quiet (mean effect (ME) = 8.4%, 95% CI = 3.5-13.2%, p = 0.004, standardized effect size (SES) = 1.06), Gabrielsson scale scores (ME = 4.8, CI95% = 0.4-9.1, p = 0.047, SES = 0.67), and interval perception (ME = 18 Hz, 95% CI = 2.7-32.4 Hz, p = 0.024, SES = 0.78). No significant difference was found for MCI or HISQUI. A period effect was observed for speech recognition in quiet (p = 0.002), Gabrielsson scale (p = 0.005), interval test (p = 0.032), and HISQUI (p = 0.039). Eighty percent of the participants kept the FS4 setting after the study period. CONCLUSION: FS4 was associated with improved music perception and speech recognition in quiet compared to HDCIS in newly implanted CI users, suggesting potential advantages of FSP strategies. N° West V Ethics Committee: 2016-A01952-49, December 28, 2016.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Fine Structure Coding in New Cochlear Implant Users with Tonotopic Fitting: a Prospective, Randomized, Double-Blind, Cross-Over Study.Clinical and experimental otorhinolaryngology · 2026
- Weighting of Spectral and Temporal Cues with n-of-m Cochlear Implant Strategies Depends on Voice Pitch.Journal of the Association for Research in Otolaryngology : JARO · 2026
- Spectro-Temporal Modulation Sensitivity Prospectively Predicts Speech-in-Noise Recognition in Cochlear Implant Users.Ear and hearing · 2026
- Novel psychoacoustic measure of spectral-temporal processing for discrete regions of the cochlear array: a proof-of-concept study.Audiology & neuro-otology · 2026
- From Approximation to Validation: Rethinking Frequency-Matched Acoustic Models of Cochlear Implants.Ear and hearing · 2026
- Spectral sparsity enables discrimination of complex-tone triads in cochlear implant listeners.The Journal of the Acoustical Society of America · 2026