Expanded Hemodialysis: From Operational Mechanism to Clinical Results.
Claudio Ronco
International Renal Research Institute, San Bortolo Hospital, Vicenza, Italy, cronco@goldnet.it.
Key points
From the paper's conclusion- Therefore, MCO membranes have also been defined with the term "high retention onset." The application of MCO/high retention onset membranes with a classic dialysis apparatus characterizes the technique called "expanded hemodialysis." The technique relies on internal filtration and backfiltration mechanism that, combined with sieving characteristics of MCO membranes, produce significant clearance o
Abstract
Research has produced interesting advances in the area of hemodialysis and related technology. Innovative composition and nanotechnology-related production techniques have produced new membranes with improved biocompatibility and enhanced permeability. Such membranes defined "medium cut-off" (MCO) have led to a new dimension of dialysis adequacy. Clearance of medium- and high-molecular-weight solutes (i.e., uremic toxins in the range of 5-30 kDa) is increased, thanks to a specific sieving profile in the region of retention onset (i.e., the molecular weight where the sieving value is 0.9). Retention onset of these membranes shifts to the right in the sieving profile compared to high-flux membranes, while the cut-off remains almost unchanged (i.e., sieving value of 0.1) with marginal albumin leakage. Therefore, MCO membranes have also been defined with the term "high retention onset." The application of MCO/high retention onset membranes with a classic dialysis apparatus characterizes the technique called "expanded hemodialysis." The technique relies on internal filtration and backfiltration mechanism that, combined with sieving characteristics of MCO membranes, produce significant clearance of large middle molecules. This mechanism is maximized if hollow fibers with reduced inner diameter are employed. The minimum technical requirement makes expanded hemodialysis application possible in every setting, where the quality of dialysis fluid meets current standards. This new technique has led to significant results in terms of biochemical targets, biological profiles, and clinical outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Expanded Hemodialysis: Mechanisms and Equipment.Contributions to nephrology · 2026
- Dialysis Membranes and Hemodialyzers.Contributions to nephrology · 2026
- Vitamin E-Coated Super High-Flux Membranes: Toward Enhanced Middle Molecule Removal and Improved Biocompatibility.Contributions to nephrology · 2026
- Unmet Clinical Needs and New Dialytic Approaches: Expanding the Therapeutic Horizon in Hemodialysis.Contributions to nephrology · 2026
- On-Line High-Volume Hemodiafiltration: Mechanisms and Equipment.Contributions to nephrology · 2026
- The Role of Online Hemodiafiltration in Contemporary Kidney CareClinical Journal of the American Society of Nephrology · 2025