Biomechanical Assessment Using MRI of Custom-Made Bovine Pericardial Tubes as Potential Aortic Replacements.
Abdulrahman Alblowi, Pierre-André Vuissoz, Siyu Lin, Olivier Bouchot, Thomas Decourselle, Jacques Felblinger, Nicla Settembre, Alain Lalande,
Department of Vascular and Endovascular Surgery, Nancy Regional University Hospital, University of Lorraine, INSERM UMRS 1116 DCAC, Nancy, France, univ-lorraine.fr. · IADI U1254, INSERM and Université de Lorraine, Nancy, France.
Key points
From the paper's conclusion- CMBPTs exhibit biomechanical properties similar to the abdominal aorta, suggesting potential for vascular applications. Both MRI sequences provided comparable results, supporting their reliability. Further research is needed to confirm long-term performance.
Abstract
INTRODUCTION: Autologous materials for vessel replacement in infected fields have high morbidity and mortality rates. Custom-made bovine pericardial tubes (CMBPTs) offer a promising alternative with advantages such as reliability, strength, and availability. However, limited biomechanical data hinder predictions of in vivo performance. This study evaluates the physiological strain and distensibility of CMBPTs in vitro under simulated abdominal aortic flow using magnetic resonance imaging (MRI). A secondary objective is to compare strain and distensibility calculations using phase contrast (PC) and steady-state free precession (SSFP) MRI sequences. METHODS: Seven CMBPTs were tested under physiological aortic conditions with a pulsatile flow rate of 1650 mL/min using in vitro MRI. PC and SSFP sequences were employed, with PC estimating velocity and strain, while SSFP assessed strain separately. Image analysis was performed using QIR-MR software. RESULTS: Strain was measured using magnitude images. The mean maximum cross-sectional areas were 419 ± 22.1 (PC) and 438.4 ± 24.3 mm2 (SSFP), while minimum areas were 374.5 ± 21.1 and 397.6 ± 23.4 mm2, respectively. The mean strain percentages were 12.1% ± 3.60% (PC) and 10.3% ± 3.20% (SSFP), with distensibility values of 1.5 ± 0.5 × 10-3 and 1.3 ± 0.4 × 10-3 mmHg-1, respectively. CONCLUSION: CMBPTs exhibit biomechanical properties similar to the abdominal aorta, suggesting potential for vascular applications. Both MRI sequences provided comparable results, supporting their reliability. Further research is needed to confirm long-term performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of Energy Dissipation Ratio in Commercial Bovine Pericardial Patches Treated with Glutaraldehyde Solution.Journal of functional biomaterials · 2026
- Assessing the displacement of thoracic aortic aneurysms with magnetic resonance imaging for a biomimetic numerical modeling.Computers in biology and medicine · 2026
- Anisotropic hyperelastic properties of porcine pericardium under equibiaxial loading: implications for aortic valve design.Frontiers in bioengineering and biotechnology · 2026
- Hemodynamic and biomechanical impact of proximal aortic surgery on the cardiovascular system: a systematic review and meta-analysis.Journal of thoracic disease · 2026
- Ex Vivo Micro-Computed Tomography-based Three-Dimensional Modeling and Biomechanical Assessment of the Human Aortic Root.Brazilian journal of cardiovascular surgery · 2026
- Crush resistance simulation of a self-expanding polymer microstent for the treatment of Fallopian tube occlusionsCurrent Directions in Biomedical Engineering · 2026