Radiology research and practice

Dual-Lumen Balloon-Assisted Onyx Embolization for Brain Arteriovenous Malformations: A Single-Center Matched Exploratory Cohort Study.

Ziyuan Huang, Qingting Hong, Fang Jia, Jinmin Chen, Chuan Chen, Baoyu Zhang, Zhendan Zhu, Weicheng Peng,

Department of Neurosurgery The Third Affiliated Hospital of Sun Yat-sen University Guangzhou China zssy.com.cn. · Department of Neurology The Third Affiliated Hospital Sun Yat-sen University Guangzhou China sysu.edu.cn.

Observational · n=36

Key points

From the paper's conclusion
  • Conclusions Dual‐lumen balloon‐assisted Onyx embolization was technically feasible and did not improve immediate complete occlusion after matching.

Abstract

BACKGROUND: Dual-lumen balloon microcatheters provide temporary flow arrest during Onyx injection and may improve embolization efficiency, but their value for brain arteriovenous malformations (AVMs) remains uncertain. We evaluated the feasibility, angiographic efficacy, procedural efficiency, and short-term safety of balloon-assisted versus conventional Onyx embolization. METHODS: We retrospectively analyzed 36 patients with intracranial AVMs treated with a dual-lumen balloon catheter and Onyx-18 and 36 contemporaneous controls treated with conventional detachable-tip single-lumen microcatheters. All included patients in both groups were treated with curative intent; when more than one embolization session was required, treatment remained a staged curative strategy rather than preoperative, preradiosurgical, or palliative adjunctive embolization. Outcomes were assessed separately at patient and procedure levels. The primary endpoint was immediate complete nidus occlusion after the final embolization session. Propensity score matching (PSM), used as an observational covariate-balancing method rather than random treatment assignment, included age, sex, Spetzler-Martin grade, rupture status, nidus location, and nidus volume and yielded 15 matched pairs. All comparative findings were considered exploratory. RESULTS: In the full dual-lumen cohort, 36 patients underwent 59 procedures. Immediate complete occlusion after the final session was achieved in 26 (72.2%) patients, near-complete occlusion in 9 (25.0%), and partial occlusion in 1 (2.8%). Across all 59 dual-lumen procedures, technical success was 100%, mean procedure time was 169.6 ± 38.7 min, and mean Onyx-18 volume was 6.43 ± 1.67 mL per procedure. Transient symptoms or complications occurred in 13 (36.1%) patients, with no documented persistent procedure-related neurological deficit. In the separate 15-pair matched analysis, immediate complete occlusion was 60.0% in both groups. The matched dual-lumen subgroup had a lower mean procedure time (176.8 ± 44.6 vs. 217.5 ± 51.8 min) and a greater mean Onyx-18 volume (7.0 ± 1.9 vs. 4.0 ± 2.2 mL). These procedure-level comparisons are reported descriptively because repeated sessions create within-patient clustering and the available data do not support a stable clustered model. CONCLUSIONS: Dual-lumen balloon-assisted Onyx embolization was technically feasible and did not improve immediate complete occlusion after matching. The lower aggregate procedure time and greater Onyx delivery observed in the matched dual-lumen subgroup are descriptive procedural signals rather than evidence of causal superiority. Treatment intent was uniformly curative in both groups and therefore was not a source of between-group imbalance; however, several angioarchitectural and operator-level covariates were incompletely captured, direct efficiency metrics were unavailable, and long-term angiographic follow-up was not uniform. Larger prospective studies with standardized curative-treatment protocols, complete procedure-level data, clustered statistical analysis, and standardized follow-up DSA are needed.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers