Device Type and Age Independently Predict Gram-Negative Cerebrospinal Fluid Device-Related Infection: A Retrospective Comparative Study.
Suleiman S Daoud, Atef F Hulliel, Sultan Jarrar, Amer Jaradat, Dana Saleh, Adam Abdallah
Neurosurgery Department Jordan University of Science and Technology Irbid Jordan just.edu.jo. · Department of Neurosurgery Brain and Spine Morsani College of Medicine University of South Florida Tampa Florida USA usf.edu.
Key points
From the paper's conclusion- We compared the clinical features, microbiological spectra, and CSF laboratory profiles of infections associated with ventriculoperitoneal (VP) shunts versus external ventricular drains (EVDs) and identified independent predictors of Gram‐negative infection.
Abstract
INTRODUCTION: Cerebrospinal fluid (CSF) device-related infection is a major complication of CSF diversion, yet the microbiological and inflammatory consequences of the device used are incompletely defined. We compared the clinical features, microbiological spectra, and CSF laboratory profiles of infections associated with ventriculoperitoneal (VP) shunts versus external ventricular drains (EVDs) and identified independent predictors of Gram-negative infection. METHOD: We performed a retrospective comparative analysis of 74 patients with culture-confirmed CSF device-related infection (42 VP, 32 EVD). Demographic, clinical, microbiological, CSF laboratory, and outcome variables were compared between device groups using the Mann-Whitney U test for continuous variables and the Fisher exact or χ 2 test for categorical variables. Standard multivariable and Firth penalized logistic regression models were fitted to identify independent predictors of Gram-negative infection. RESULTS: Patients with EVD infection were older than those with VP infection (median 21.5 vs. 4.2 years; p = 0.029), and a smaller proportion were pediatric (47% vs. 69%). Underlying indications differed (p = 0.004), with hemorrhagic and tumor-related indications more common in the EVD group. Gram-positive organisms predominated in the VP group (30/42, 71%) and Gram-negative organisms in the EVD group (19/32, 59%) (p = 0.006); coagulase-negative staphylococci and Acinetobacter baumannii were the most frequent Gram-positive and Gram-negative isolates, respectively. In multivariable analysis, EVD (adjusted OR 3.44, 95% CI 1.20-9.88; p = 0.022) and adult age (adjusted OR 4.38, 95% CI 1.52-12.59; p = 0.006) were independently associated with Gram-negative infection. CONCLUSION: Device type and patient age strongly structure the microbiology and inflammatory profile of CSF device-related infection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative epidemiology and outcomes of gram-negative and non-gram-negative External Ventricular Drain (EVD)-related infections: a 10-year single-center cohort study.Neurosurgical review · 2026
- Impact of initial disease severity and metabolic stress on mortality in patients with suspected external ventricular drain-associated infection.Neurosurgical review · 2026
- Microbiological Spectrum and Antimicrobial Resistance Patterns of Cerebrospinal Fluid Isolates from Neurosurgical Intensive Care and Ward Patients: A 10-Year Single-Center Study.Journal of clinical medicine · 2026
- Incidence, risk factors, and microbial spectrum of external ventricular drain-related infections among adult neurocritical care patients: A systematic review and meta-analysis.Journal of the Intensive Care Society · 2026
- Efficacy of Standard Meropenem Dosing in Healthcare-Associated Meningitis: Is It Universal?Anaesthesia, critical care & pain medicine · 2026
- Antibiotic susceptibility of Gram-negative bacteria in cerebrospinal fluid compared with Mueller-Hinton broth and artificial cerebrospinal fluidInternational Journal of Antimicrobial Agents · 2026