Characteristics of Ultraviolet–Visible–Near‐Infrared Transmittance Spectra of Particle‐Contaminated Hydraulic Oil

Zhenhong Qi, Xiangdong Kong

Key points

From the paper's conclusion
  • It was determined that the detector operating near 1030 nm serves as a relatively suitable option for the transmittance spectrum detection of hydraulic oil.

Abstract

Most faults in the hydraulic systems of engineering machinery are related to changes in the composition of hydraulic oil, among which particle contamination is the most common type. To provide spectral dimension with abundant information content of hydraulic oil for hydraulic system monitoring, this study focuses on the characteristics of transmittance spectra of hydraulic oil contaminated by particles. L‐HM 68 hydraulic oil samples contaminated by SiO 2 , Fe, and Cu particles of 25 μm, 10 μm, and 5 μm were prepared, and the particle mass concentration ranged from 0 to 10000 mg/L. Levels of contamination of these oil samples under the ISO 4406 standard were determined by a contaminant particle counter, and their transmittance spectra were obtained by an assembly device in the wavelength range of 200–2500 nm. It was found that the obvious absorption valleys of spectral transmittance curves of these oil samples are mainly distributed in ultraviolet (UV) and near‐infrared (NIR) bands. The minimum transmittance values of these absorption valleys are located near seven characteristic wavelengths: 340 nm, 920 nm, 1030 nm, 1200 nm, 1390 nm, 1750 nm, and 2250 nm. Spectral transmittance curves of these oil samples exhibit distinct variation characteristics within each order of magnitude of mass concentration. Smaller contaminant particles lead to a faster drop in the spectral transmittance curve of hydraulic oil with increasing mass concentration. Transmittance at each characteristic wavelength shows exponential relationships with mass concentration. It was determined that the detector operating near 1030 nm serves as a relatively suitable option for the transmittance spectrum detection of hydraulic oil. For the relationship between transmittance at the characteristic wavelengths and the level of contamination by particles according to ISO 4406 of hydraulic oil, the size threshold of ≥ 14 μm is more suitable for distinguishing various types of contaminant particles.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Characteristics of Ultraviolet–Visible–Near‐Infrared Transmittance Spectra of Particle‐Contaminated Hydraulic Oil — Science Skim