Journal of Interventional Cardiology

Zero‐Contrast Percutaneous Left Atrial Appendage Closure in High‐Risk Patients With Mitral Valve Prosthesis: Feasibility, Safety, and Midterm Outcomes

Mert Doğan, Ahmet Hakan Ateş, Uğur Canpolat, Ahmet Kıvrak, Uğur Nadir Karakulak, Cem Çöteli, Hikmet Yorgun, Mehmet Levent Sahiner,

Key points

From the paper's conclusion
  • Conclusions Percutaneous zero‐contrast LAAC was technically feasible and was associated with favorable procedural safety in this small, selected cohort of high‐risk patients with prior MVR.

Abstract

Background Patients with mechanical or bioprosthetic mitral valve replacement (MVR) face a persistently high risk for thromboembolic events, even with optimal oral anticoagulation (OAC). Percutaneous left atrial appendage closure (LAAC) offers an alternative, yet evidence in this complex, high‐risk population remains limited. Objectives This study aimed to assess the immediate and midterm feasibility and safety of percutaneous zero‐contrast LAAC in patients with prior MVR and persistent high thromboembolic/bleeding risk. Methods This single‐center retrospective study included 18 high‐risk patients (12 mechanical, 6 bioprosthetic MVR) who underwent zero‐contrast LAAC between January 2015 and May 2025. Indications included OAC‐refractory LAA thrombus ( n = 9), major bleeding ( n = 4), recurrent stroke ( n = 2), surgical residual leak closure ( n = 2), and LAA electrical isolation ( n = 1). All LAAC procedures were performed under combined transesophageal echocardiographic and fluoroscopic guidance without iodinated contrast administration; in two patients, contrast was used exclusively for a concomitant transcatheter valve intervention. Results All procedures were successful without major periprocedural complications. During a median follow‐up of 15.0 months (range 3–60), five patients (27.8%) died and one (5.6%) experienced major gastrointestinal bleeding. Crucially, no patient experienced ischemic stroke, clinically detected device‐related thrombus, or device embolization. Cumulative event‐free survival rates were 94% at 3 months and 74% at 12 months. Conclusions Percutaneous zero‐contrast LAAC was technically feasible and was associated with favorable procedural safety in this small, selected cohort of high‐risk patients with prior MVR. No thromboembolic events were observed during follow‐up; however, given the small single‐arm cohort and the substantial competing mortality, these findings should primarily be interpreted as evidence of procedural feasibility and short‐term procedural safety rather than durable thromboembolic protection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers