Journal of Chemistry

Zn 2+ Adsorption From Aqueous Solution by an APTES‐Functionalised TiO 2 –Charred Bagasse Composite: Optimisation by Response Surface Methodology

Mmathapelo Pitso, Kgalalelo Thapeli, Evans Suter, Stephen Barasa, Vhahangwele Masindi, Phumudzo Budeli, Banza Musamba, Teketel Girma Gindose

Key points

From the paper's conclusion
  • These results demonstrate substantial Zn 2+ uptake and repeated use in synthetic solutions, supporting further evaluation of regeneration efficiency, component stability and performance in complex aqueous systems.

Abstract

Zinc contamination threatens water quality and aquatic ecosystems, while sugarcane bagasse remains an underutilised agro‐industrial residue. An APTES‐functionalised TiO 2 –charred bagasse composite (APTES/TiO 2 –CB) was synthesised, characterised and evaluated for Zn 2+ removal from aqueous media. FTIR and SEM–EDX supported the presence of TiO 2 and APTES‐derived groups, while N 2 adsorption–desorption analysis identified a mesoporous composite with a specific surface area of 42.88 m 2 g −1 , total pore volume of 0.0838 cm 3 g −1 and average pore diameter of 7.82 nm. A face‐centred central composite design coupled with response surface methodology evaluated operating‐variable interactions and optimised removal. The quadratic model was significant ( F = 70.95, p < 0.0001), with R 2 = 0.9876 and nonsignificant lack of fit ( p = 0.1893). Numerical optimisation predicted 97.85% removal at pH 6.03, an initial Zn 2+ concentration of 92.67 mg·L −1 and an adsorbent dosage of 0.354 g·L −1 . Triplicate validation yielded 98.87 ± 0.64% removal, with a relative prediction error of 1.04%. The highest measured uptake was 573.33 mg·g −1 , while the fitted Langmuir capacity was 635.45 mg·g −1 . The pseudo‐second‐order model estimated equilibrium uptake within 6.12% of the experimental value. Removal increased from 91.12% at 298 K to 98.40% at 328 K. After six adsorption–desorption cycles, the composite retained 63.39% of its initial capacity. These results demonstrate substantial Zn 2+ uptake and repeated use in synthetic solutions, supporting further evaluation of regeneration efficiency, component stability and performance in complex aqueous systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Zn 2+ Adsorption From Aqueous Solution by an APTES‐Functionalised TiO 2 –Charred Bagasse Composite: Optimisation by Response Surface Methodology — Science Skim