Monitoring and Early Warning Method for Hydrogen‐Induced Cracking in E690 Steel Based on Resistance Corrosion Monitoring Principle
Peichang Deng, Shuo Yang, Junhao Zeng, Jingquan Wu, Jiezhen Hu, Fangming Wu, Limei Gan
Key points
From the paper's conclusion- The results demonstrated that during the elastic deformation stage of the hydrogen‐charged E690 steel, the resistance ratio (K) ranged from 0.98 to 1.04, whereas during the plastic deformation stage in the SSRT process, this range expanded to 0.99–1.20.
Abstract
Hydrogen‐induced cracking (HIC) is sudden and concealed, posing a high risk of economic loss and catastrophic accidents. Research into HIC monitoring methods is essential for mitigating these impacts. Based on the principle of resistance corrosion monitoring, this study integrates the offset‐compensated ohmic method and the four‐wire method to develop a high‐precision resistance corrosion monitoring technique. Using E690 steel as the research material, electrochemical hydrogen charging was performed to simulate the hydrogen charging process, and a slow strain rate test (SSRT) was conducted to mimic the cracking process of hydrogen‐charged materials. The developed high‐precision resistance corrosion monitoring method was then applied to monitor changes in electrical resistance. The results demonstrated that during the elastic deformation stage of the hydrogen‐charged E690 steel, the resistance ratio (K) ranged from 0.98 to 1.04, whereas during the plastic deformation stage in the SSRT process, this range expanded to 0.99–1.20. In addition, hydrogen diffused and accumulated in specific regions within the material, obstructing dislocation movement. The longer the hydrogen charging time, the stronger the obstruction, resulting in a greater magnitude of change in the K value (represented by the slope). The slope of the nonhydrogen‐charged specimen was 1.15, whereas the slopes were 1.59, 1.80, and 2.33 for the specimens hydrogen‐charged for 4, 24, and 48 h, respectively. The electrical resistance exhibited high sensitivity during the HIC corrosion process, enabling sensitive monitoring of HIC via resistance corrosion monitoring technology. The online monitoring method for HIC based on the principle of resistance corrosion monitoring provides a novel approach for the potential early warning of HIC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Investigation of Welded Joints of Pipelines from an Existing Gas Transmission Network Exposed to Hydrogen—Part I: Structure, Mechanical Properties and Susceptibility to Hydrogen EmbrittlementMetals · 2026
- Hydrogen charging effect on the stress corrosion cracking of Alloy 690 tubes with dents in a lead-containing high temperature caustic environmentCorrosion Communications · 2026
- Effects of sensitization on hydrogen embrittlement behavior in 304 stainless steelMaterials & Design · 2025
- Coupled stress–diffusion modeling of hydrogen embrittlement in API X52 and X70 pipeline steelsJournal of Materials Research and Technology · 2026
- Study of the Resistance of Low-Alloy Pipe Steels to Hydrogen-Induced CrackingJournal of Manufacturing and Materials Processing · 2026
- Hydrogen-Induced Damage Evolution and Quasi-Cleavage Cracking in API X70 Pipeline Girth Welds Under Blended CH4-H2 EnvironmentsCrystals · 2026