From the paper's conclusion
  • The study proposes a methodology for estimating IAQ through an indicator called the Proposed Indoor Air Quality Index (PIAQI) in a passenger transit area at Brindisi Airport, Italy.

Abstract

Indoor air quality (IAQ) is identified as a health protection measure, especially in heavily trafficked public spaces, where pollutant variations are influenced by human activities, building characteristics, ventilation, infiltration, and external atmospheric conditions. The study proposes a methodology for estimating IAQ through an indicator called the Proposed Indoor Air Quality Index (PIAQI) in a passenger transit area at Brindisi Airport, Italy. It is calculated based on indoor concentrations of CO 2 , PM 2.5 , and PM 10 . The main objective is to evaluate the possibility of predicting PIAQI without using the variables directly involved in its formula as predictors. For this purpose, a dataset was constructed consisting of indoor measurements collected within an airport, historical weather data, and outdoor air pollution data provided through public platforms. The records were imported using the C# language into a SQL Server database and temporally aligned through an SQL view. The analytical dataset combined high‐frequency indoor sensor measurements, historical meteorological data, and outdoor air‐pollution data through hourly temporal alignment. Subsequently, a feature importance analysis was performed on a reduced set of observations using the LightGBM regression model implemented in ML.NET through the drop column importance method. The variables with a positive contribution to the R 2 coefficient loss were retained for the subsequent stage. A sample of 1 million observations was extracted from the SQL View and used in Azure Machine Learning to train seven regression algorithms. They were calculated, and from the comparison, it was found that the XGBoost regressor model had the best performance. The study showed that PIAQI estimates the combination of alternative indoor aerosol measurements with meteorological variables and outdoor pollutant concentrations, even after removing indoor CO 2 , PM 2.5 , and PM 10 from the predictor set. For internal validation, the data were randomly divided into 70% for training and 30% for holdout evaluation. XGBoost regressor achieved the best internal performance, with R 2 = 0.9675, MAE = 2.32, and RMSE = 4.04. A complementary chronological evaluation, in which the first 70% of the observations were used for training and the final 30% for testing, produced R 2 = −1.3905, MAE = 33.50, and RMSE = 41.90. This performance decrease indicates that random splitting yields optimistic estimates when temporally adjacent observations occur in both subsets. The methodology serves as a foundation for the development of intelligent monitoring, warning, ventilation control, and filtration control systems in crowded public spaces, as well as for taking appropriate preventive measures.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers