International Journal of Clinical Practice

Blocking Antibody Burden Stratifies Immune Heterogeneity to Guide Precise Immunotherapy With Cyclosporine A in Recurrent Implantation Failure

Ling Guo, Shuteng Zhang, Jingjing Li, Yanxia Yu, Qingxia Meng, Tianqi Du

Observational · n=427

Key points

From the paper's conclusion
  • Background To evaluate whether the burden of negative peripheral blood blocking antibody (BA) items can stratify recurrent implantation failure (RIF) patients for cyclosporine A (CsA) treatment response.

Abstract

Background To evaluate whether the burden of negative peripheral blood blocking antibody (BA) items can stratify recurrent implantation failure (RIF) patients for cyclosporine A (CsA) treatment response. Methods This retrospective cohort study included 427 women (517 frozen embryo transfer cycles) with RIF. BA panel measured blocking activity against CD3, CD4, CD8, and CD56. Cycles were grouped by BA burden (0–2 vs. 3‐4 negative items) and further classified by CsA use. Adjusted modified Poisson regression with generalized estimating equations and interaction terms was applied to estimate relative risks (RR) and effect modification. Results In the low‐burden subgroup (0–2, n = 335), CsA was associated with moderate improvements (implantation RR = 1.36, 95% CI 1.04–1.78; clinical pregnancy RR = 1.42, 95% CI 1.11–1.81; live birth RR = 1.43, 95% CI 1.05–1.96). In the high‐burden subgroup (3‐4, n = 182), effects were substantially larger (implantation RR = 2.95, 95% CI 1.64–5.31; clinical pregnancy RR = 2.73, 95% CI 1.56–4.76; live birth RR = 2.86, 95% CI 1.53–5.32). Interaction was significant for implantation (RR = 2.17, p = 0.019) and clinical pregnancy (RR = 1.92, p = 0.036), and borderline for live birth (RR = 1.99, p = 0.055). Absolute differences in the high‐burden group reached 29.3% for implantation, 32.8% for clinical pregnancy, and 26.5% for live birth. Conclusions BA negativity burden modifies CsA treatment effect, with substantially greater benefits in patients with three to four negative items. This pragmatic blood‐based biomarker may help identify RIF patients most likely to respond to CsA, supporting precision immunomodulation. Prospective validation is warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Blocking Antibody Burden Stratifies Immune Heterogeneity to Guide Precise Immunotherapy With Cyclosporine A in Recurrent Implantation Failure — Science Skim