Mechanical Properties, Damage Evolution, and Field Performance of Energy‐Dissipating Shaft Lining Concrete for an Ultradeep Shaft
Xi Wang, Hongguang Ji, Binhui Liu, Peng Xiang, Xingquan Liu, Danyang Kuang, Zhen Liu, Xiaoqi Wang,
Key points
From the paper's conclusion- The results showed that steel‐like synthetic fibers provided limited strength enhancement, whereas galvanized steel fibers and stainless steel fibers markedly improved the mechanical performance.
Abstract
Ultradeep shaft linings are exposed to complex deep‐engineering environments characterized by high in situ stress, groundwater pressure, and repeated construction and mining disturbances, which increase the risk of brittle damage and structural instability. To improve the deformation adaptability and energy‐dissipation capacity of shaft lining concrete, this study investigated fiber‐reinforced energy‐dissipating concrete based on an ultradeep shaft project in the Sanshandao gold mine. Steel‐like synthetic fibers, galvanized steel fibers, and stainless steel fibers were incorporated at dosages of 1.5% and 2.0%. Mechanical tests, impact energy index tests, acoustic emission (AE) monitoring, and microstructural characterization were conducted to evaluate the effects of fiber type and dosage on mechanical performance, energy dissipation, and damage evolution. The results showed that steel‐like synthetic fibers provided limited strength enhancement, whereas galvanized steel fibers and stainless steel fibers markedly improved the mechanical performance. In particular, 2.0% galvanized steel fibers increased the compressive and splitting tensile strengths by 25.7% and 68%, respectively. The three fiber types reduced the impact energy index by 44%–48%, 51%–54%, and 54%–58%, respectively, indicating reduced brittleness and improved resistance to impact‐induced instability. AE monitoring further revealed that galvanized steel fibers delayed crack localization and rapid damage development, whereas fiber bridging, interfacial friction, and progressive pull‐out contributed to sustained post‐peak load‐bearing and energy dissipation. SEM/EDS observations provided microstructural evidence for the improved fiber–matrix interaction and crack‐bridging mechanisms. Based on the comprehensive experimental results, concrete containing 2.0% galvanized steel fibers was selected for field application in the ultradeep shaft. Approximately 40 days of in situ strain monitoring showed gradually stabilized deformation without abrupt changes or sustained divergence. These results provide preliminary field evidence that the proposed energy‐dissipating concrete can mitigate brittle instability and improve the service stability of shaft linings in deep engineering environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Steel Fiber Content on the Mesoscopic Damage Mechanism of Cemented Gangue Backfill.Materials (Basel, Switzerland) · 2026
- Influence of Fibers on the Flexural Performance and Damage Evolution Behavior of Coal-Based Solid Waste Grouting Material.Materials (Basel, Switzerland) · 2026
- Research on the Stability of Arc-Fractured Rock–Concrete Composites: Mechanical Response and Energy EvolutionInternational Journal of Geomechanics · 2026
- Steel Fiber Reinforced Concrete Segments for Shield Tunnels: A Comprehensive Review of Mechanical Performance, Design Methods and Future DirectionsBuildings · 2025
- Radiation shielding performance and mechanical behavior of hybrid fiber-reinforced sustainable concrete.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Coupled thermo-mechanical simulation of lining cracking evolution and sealing system mechanical response in CAES lined rock caverns using finite-discrete element methodTunnelling and Underground Space Technology · 2026