International Journal of Energy Research

Optimal Sizing of a Battery Energy Storage System for Industrial Customers Using Stochastic Programming for Economic Operations

Madia Safdar, Behnam Mohammadi-Ivatloo, Ghulam Amjad Hussain, Arslan Bashir

Key points

From the paper's conclusion
  • These findings demonstrate the potential of the proposed stochastic framework to support cost effective BESS sizing for industrial consumers under demand uncertainty, while highlighting that the achievable benefits depend strongly on local tariff structures and solar resources.

Abstract

Industrial electricity consumers are charged not only for energy consumption but also for peak power demand during a billing period, called as demand charge (DC). Battery energy storage systems (BESS) can help offset DC through peak shaving. By combining BESS with renewable energy sources (RESs), such as photovoltaics (PV) generation, industries can significantly reduce both energy demand from grid and DC, resulting in the optimal use of RES and BESS. This paper presents an optimal BESS sizing framework, determining its optimal size and charge/discharge strategy while considering both peak demand reduction and real‐time price variations. The model is formulated using stochastic mixed‐integer programming (MIP) and validated through simulations on an industrial load using energy tariffs from Finland and Georgia (USA), and PV generation to account for variations in electricity tariffs and DC across regions. Load uncertainty is modeled by using Monte–Carlo simulation (MCS). Sensitivity analyses are conducted to evaluate the effects of BESS charge/discharge rates, BESS degradation and PV generation on the BESS sizing, energy cost and DC. In addition, an economic analysis is performed to evaluate the economic feasibility of the proposed system in terms of its net present worth (NPW), break‐even period and internal rate of return (IRR). The results with charge rate of 1C indicate that, relative to reference case without BESS and PV, the deployment of a standalone BESS reduces energy costs by 26.37% and DC by 42.15% which comprises of both the active and reactive power demand components, factoring in the battery costs and operational constraints. When PV generation is integrated with the option to export excess electricity to the grid, the energy cost savings increased to 57.97%, and DC reduced by 63.50%, furthermore the payback period can only be 2.4 years for a region with substantial PV generation throughout the year. These findings demonstrate the potential of the proposed stochastic framework to support cost effective BESS sizing for industrial consumers under demand uncertainty, while highlighting that the achievable benefits depend strongly on local tariff structures and solar resources.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers