Fluoroscopy-Guided Localization and Retrieval of a Migrated Extrapelvic Intrauterine Device: A Case Report.
Mohammad Haekal, Caroline Gladys Puspita, Tiara Sirinding Mangiwa, Mazkuroh Urfah, Gde Suardana
Department of Obstetric and Gynecology, Harapan Kita National Women and Children Health Centre, Jakarta, Indonesia.
Key points
From the paper's conclusion- Early clinical suspicion and a structured imaging approach are essential for the diagnosis of extrauterine IUD migration. When pelvic ultrasonography is inconclusive, abdominal radiography with uterine markers can improve localization. Fluoroscopic guidance improves intraoperative localization and facilitates safe minimally invasive retrieval of extrapelvic IUD migration while minimizing surgical morbidity.
Abstract
BACKGROUND: Intrauterine devices (IUDs) are widely used as a highly effective method of contraception. Although rare, uterine perforation is a serious complication, occurring in approximately 1 per 1000 insertions. This case underscores the value of laparoscopy in enabling accurate diagnosis and immediate removal of an occult extrauterine IUD migration. In addition, fluoroscopy guidance improves localization accuracy, facilitates precise retrieval, and may help prevent laparotomy. CASE PRESENTATION: This case presents a 25-year-old woman presented with progressive abdominal pain 1 year after IUD insertion. Physical examination revealed no involuntary guarding and the IUD strings were not visible. Transvaginal ultrasonography showed no evidence of a myometrial defect. An abdominal x-ray with uterine marker demonstrated extrapelvic migration of the IUD. The patient subsequently underwent fluoroscopy-assisted laparoscopic retrieval. Intraoperative findings revealed a uterine scar and dense adhesions between the IUD and the omentum. CONCLUSION: Early clinical suspicion and a structured imaging approach are essential for the diagnosis of extrauterine IUD migration. When pelvic ultrasonography is inconclusive, abdominal radiography with uterine markers can improve localization. Fluoroscopic guidance improves intraoperative localization and facilitates safe minimally invasive retrieval of extrapelvic IUD migration while minimizing surgical morbidity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Delayed extrauterine copper IUD identified 1 month after repeat insertion in a woman with multiple sclerosis: a case report.International journal of surgery case reports · 2026
- The "Lost" and "Found" IUD: a case of concurrent intrauterine and intraperitoneal devices with delayed recognition.International journal of surgery case reports · 2026
- Laparoscopic management of an intramurally migrated intrauterine contraceptive device (IUCD) without serosal perforation: a case report.International journal of surgery case reports · 2026
- Delayed intravesical migration of an intrauterine device (IUD) and subsequent successful pregnancy: a case report of diagnostic and surgical challenges.Journal of medical case reports · 2026
- Intravesical migration of an intrauterine contraceptive device complicated by giant bladder calculus formation: a case report.International journal of surgery case reports · 2026
- Intrauterine device migration into the bladder with resultant bladder stone formation: a case report.Frontiers in medicine · 2026