NanoScope-Assisted Arthroscopic Repair of a Full-Thickness Supraspinatus Tear With Concomitant Shoulder Pathology: A Case Report.
Jonathan Brutti, Juan Rayo Parra, Klaudia Greer, Zachary Grand, Jan Pieter Hommen, Cesar Ceballos
Florida International University Herbert Wertheim College of Medicine 11200 SW 8th Street Miami 33199 Florida USA fiu.edu. · Rutgers New Jersey Medical School 185 S Orange Avenue Newark 07103 New Jersey USA rutgers.edu.
Key points
From the paper's conclusion- Conclusion This case demonstrates the technical feasibility of NanoScope‐assisted arthroscopic repair of a full‐thickness supraspinatus tear with concomitant shoulder pathology.
Abstract
CASE: A 62-year-old right-hand-dominant woman presented with progressive atraumatic left shoulder pain, weakness, and limited range-of-motion (ROM) refractory to conservative management. Examination revealed weakness of the supraspinatus and positive impingement signs. MRI demonstrated a medially retracted full-thickness supraspinatus tear with subacromial bursitis and acromioclavicular arthrosis. Intraoperative assessment identified a partial tear of the biceps tendon at the superior labral insertion, a degenerative Type-II superior labrum anterior-to-posterior (SLAP) lesion, posterior-superior labral tearing without complete detachment, and glenoid chondromalacia. She underwent NanoScope-assisted arthroscopic double-row supraspinatus repair with biceps tenotomy, labral debridement, glenoid chondroplasty, subacromial decompression, acromioplasty, and distal claviculectomy. At 6 weeks, ultrasound (US) demonstrated an intact-appearing supraspinatus repair without retraction. At 1-year telehealth follow-up, the patient reported favorable patient-reported outcomes, including an American Shoulder and Elbow Surgeons score of 88/100, shoulder surgery questionnaire 8 score of 92.5/100, single assessment numeric evaluation (SANE) scores of 95% for the left shoulder and 90% for the right shoulder, and visual analog scale (VAS) pain score of 0/10. CONCLUSION: This case demonstrates the technical feasibility of NanoScope-assisted arthroscopic repair of a full-thickness supraspinatus tear with concomitant shoulder pathology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Arthroscopic Supraspinatus Repair With Bioinductive and Mechanical Reinforcement Using a Biocomposite Scaffold.Arthroscopy techniques · 2026
- Arthroscopic repair versus open repair for subscapularis tears with or without concomitant supraspinatus tears: a systematic review and meta-analysis of comparative studies.Musculoskeletal surgery · 2026
- Marginal Convergence Repair Technique for Partial Articular-Sided Rotator Cuff Tears.Arthroscopy techniques · 2026
- Surgical Repair Strategies for Full-Thickness Supraspinatus Tears: A Systematic Review and Meta-Analysis.Medical sciences (Basel, Switzerland) · 2026
- Irreparable Posterosuperior Rotator Cuff Tears Treated With InSpace Balloon With or Without Arthroscopic Subscapularis Repair: Short-Term Clinical Outcomes in a Multicenter Retrospective Study.Arthroscopy, sports medicine, and rehabilitation · 2026
- Arthroscopic and MRI Visibility of the Rotator Cable in Supraspinatus Tears: Agreement, Associated Factors, and Relationship with Preoperative Range of Motion.Journal of clinical medicine · 2026