Case reports in orthopedics

Induced Membrane Reconstruction of a 6-cm Ulnar Defect With Concurrent Revision Bone Grafting of Radial Nonunion Following Gustilo-Anderson Type IIIB Open Forearm Fracture: A Case Report.

John N Manfredi, Abdullah B Chandasir, Mitchell Lomis, Brent Prenger, Humzah Ali, Kyra Urquhart-Foster, Caleb J Bischoff, Abrar Adil Ansari

Medical College of Georgia Augusta Georgia USA gru.edu. · Department of Orthopedics Research University of Missouri School of Medicine Columbia Missouri USA missouri.edu.

Case report

Key points

From the paper's conclusion
  • We report a 31-year-old male who sustained a Gustilo-Anderson grade IIIB open fracture of the radius and ulna following a high-energy dirt bike injury, complicated by Serratia marcescens fracture-related infection and septic nonunion.

Abstract

The induced membrane technique (IMT) is a two-stage reconstructive procedure for critical-sized bone defects. We report a 31-year-old male who sustained a Gustilo-Anderson grade IIIB open fracture of the radius and ulna following a high-energy dirt bike injury, complicated by Serratia marcescens fracture-related infection and septic nonunion. Intraoperative debridement at Stage 1 revealed a 6-cm defect of the ulna, which was managed with an antibiotic-impregnated polymethylmethacrylate (PMMA) spacer. A concomitant radial nonunion, identified on postdebridement CT, was addressed at Stage 2 with concurrent revision open reduction and internal fixation (ORIF) and autogenous femoral bone grafting. Culture-directed oral antibiotic therapy was administered following Stage 1. Mature bridging callus was noted at 6 months and confirmed at both bones at approximately 22 months postinjury, with infection eradication confirmed at Stage 2. Prior to subsequent elbow procedures, the patient demonstrated a Mayo Elbow Performance Score of 65 (fair), with an elbow arc of motion of 60°-140° and forearm rotation of 70° pronation and 75° supination. This case illustrates the utility of IMT for ulnar reconstruction in the setting of fracture-related infection, and highlights a forearm-specific biomechanical consideration: Fixing the ulna at a set length via the IMT spacer construct while shortening the radius for nonunion compression may alter radioulnar variance, a single-case observation that we hypothesize could have implications for DRUJ and elbow mechanics and warrants further study.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers