Induced Membrane Reconstruction of a 6-cm Ulnar Defect With Concurrent Revision Bone Grafting of Radial Nonunion Following Gustilo-Anderson Type IIIB Open Forearm Fracture: A Case Report.
John N Manfredi, Abdullah B Chandasir, Mitchell Lomis, Brent Prenger, Humzah Ali, Kyra Urquhart-Foster, Caleb J Bischoff, Abrar Adil Ansari
Medical College of Georgia Augusta Georgia USA gru.edu. · Department of Orthopedics Research University of Missouri School of Medicine Columbia Missouri USA missouri.edu.
Key points
From the paper's conclusion- We report a 31-year-old male who sustained a Gustilo-Anderson grade IIIB open fracture of the radius and ulna following a high-energy dirt bike injury, complicated by Serratia marcescens fracture-related infection and septic nonunion.
Abstract
The induced membrane technique (IMT) is a two-stage reconstructive procedure for critical-sized bone defects. We report a 31-year-old male who sustained a Gustilo-Anderson grade IIIB open fracture of the radius and ulna following a high-energy dirt bike injury, complicated by Serratia marcescens fracture-related infection and septic nonunion. Intraoperative debridement at Stage 1 revealed a 6-cm defect of the ulna, which was managed with an antibiotic-impregnated polymethylmethacrylate (PMMA) spacer. A concomitant radial nonunion, identified on postdebridement CT, was addressed at Stage 2 with concurrent revision open reduction and internal fixation (ORIF) and autogenous femoral bone grafting. Culture-directed oral antibiotic therapy was administered following Stage 1. Mature bridging callus was noted at 6 months and confirmed at both bones at approximately 22 months postinjury, with infection eradication confirmed at Stage 2. Prior to subsequent elbow procedures, the patient demonstrated a Mayo Elbow Performance Score of 65 (fair), with an elbow arc of motion of 60°-140° and forearm rotation of 70° pronation and 75° supination. This case illustrates the utility of IMT for ulnar reconstruction in the setting of fracture-related infection, and highlights a forearm-specific biomechanical consideration: Fixing the ulna at a set length via the IMT spacer construct while shortening the radius for nonunion compression may alter radioulnar variance, a single-case observation that we hypothesize could have implications for DRUJ and elbow mechanics and warrants further study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Forearm Nonunion and Segmental Bone Defects: A Focused Review of Masquelet Reconstruction and Free Vascularized Bone Grafting.Orthopedic research and reviews · 2026
- Custom Antibiotic-Coated Intramedullary Nails for Infected Tibial and Femoral Nonunions: Retrospective Cohort Study and Surgical Technique.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2026
- Clinical Outcomes of PMMA Spacers in the Induced Membrane Technique: A Systematic Review and Meta-AnalysisSci · 2026
- The road to the Pearl-String Technique: lessons learned from early IMT modifications using RIA autograft and cancellous allograft granules.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
- A High-Energy Military Femoral Fracture With Multidrug-Resistant Infection: A Case Report.The American journal of case reports · 2026
- Ilizarov Accordion Maneuver for Infected Nonunion of Both-Bone Forearm Fracture: A Case Report.JBJS case connector · 2026