Intraoperative Ultrasound-Guided Repair of Penile Fracture: A Case Report.
Hoi-Lung Wong, Omar Wai-Kiu Tsui, Brian Sze-Ho Ho, Ada Tsui-Lin Ng
Division of Urology, Department of Surgery, Queen Mary Hospital, Hong Kong, China, qmh.org.hk. · Division of Urology, Department of Surgery, The University of Hong Kong, Hong Kong, China, hku.hk.
Key points
From the paper's conclusion- We conclude that IO-USG-guided repair of penile fracture facilitates rapid identification of the injury site, accurate assessment of hematoma burden, and targeted surgical approach that avoids penile degloving while ensuring complete repair.
Abstract
Penile fracture is a rare urological emergency resulting from rupture of the tunica albuginea during blunt trauma to an erect penis, typically during sexual intercourse. While immediate surgical repair is associated with superior outcomes compared with conservative management, delayed treatment can lead to significant long-term complications including penile curvature in 30% of cases and erectile dysfunction in 50%-62% of cases. We present the case of a 22-year-old patient who sustained a penile fracture while manipulating his erect penis. Clinical examination revealed penile swelling, bruising, and a 60° leftward curvature. Intraoperative ultrasound (IO-USG) with a linear probe precisely localized a tunica albuginea defect in the right corpus cavernosum, enabling a minimally invasive 1.5-cm transverse incision directly over the fracture site. This approach avoided complete penile degloving, reduced operative time and blood loss, and facilitated complete clot evacuation and defect closure using interrupted 3-0 PDS sutures. Postoperative recovery was uneventful, with the patient discharged the following day and reporting normal erectile function and no penile deformity at the 3-month follow-up. A literature review confirms that while preoperative imaging is commonly utilized for surgical planning, IO-USG guidance for real-time fracture localization and incision placement remains rarely reported. Although MRI and CT offer superior soft tissue resolution, they are limited by availability, time constraints, and radiation exposure. IO-USG is readily accessible and noninvasive; although operator-dependent, it provides high-resolution real-time guidance that enables smaller incisions, minimizes postoperative complications such as glans numbness, and optimizes functional outcomes. We conclude that IO-USG-guided repair of penile fracture facilitates rapid identification of the injury site, accurate assessment of hematoma burden, and targeted surgical approach that avoids penile degloving while ensuring complete repair.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Penile fracture with rupture of both corpora cavernosa and complete urethral disruption: a case report.International journal of surgery case reports · 2026
- Penile Replantation in Severe Polytrauma: A Rare Case With Surgical Insights.Cureus · 2026
- Immediate Repair for Laceration of the Tunica Albuginea of the Corpora Cavernosa and Penile Urethral Injury Caused by Blunt Trauma to the Flaccid Penis: A Case ReportIJU Case Reports · 2026
- Postoperative Management After Penile Fracture Surgery: Intra-operative Drainage Is Not Associated With Early Morbidity Reduction (FRACT AFUF project).The French journal of urology · 2026
- Risk factors for early penile curvature following surgical repair of penile fracture: a multicenter retrospective study from FRACT'AFUF.The French journal of urology · 2026
- Peripheral Intravenous Cannula Fracture With Intravascular Retention: Early Diagnosis and Management in a Case Report and Literature ReviewCureus · 2026