Challenging the Concept of Inertness: Hypersensitivity Reaction to a PTFE Vascular Graft-A Case Report.
Gabriela Katharina Pomper, Ferdinand Slišurić, Mirela Frančina, Božica Lovrić, Marin Mamić, Ivan Vukoja
Department for General Surgery General Hospital Požega Požega Croatia. · Department of Pathology General Hospital Požega Požega Croatia.
Key points
From the paper's conclusion- We report a 55‐year‐old man with end‐stage renal disease on chronic hemodialysis who underwent resection of a symptomatic aneurysmal segment of a native brachiocephalic arteriovenous fistula (AVF) and interposition of a 6‐mm PTFE graft because the remaining cephalic vein was markedly calcified and unsuitable for primary reconstruction.
Abstract
Polytetrafluoroethylene (PTFE) grafts are widely used for hemodialysis access when autologous vascular reconstruction is not feasible, but true hypersensitivity reactions are exceptionally rare and may closely mimic graft infection. We report a 55-year-old man with end-stage renal disease on chronic hemodialysis who underwent resection of a symptomatic aneurysmal segment of a native brachiocephalic arteriovenous fistula (AVF) and interposition of a 6-mm PTFE graft because the remaining cephalic vein was markedly calcified and unsuitable for primary reconstruction. Four days after surgery, progressive erythema, induration, and vesiculobullous lesions developed around the operative site. Infection, vascular compromise, hematoma, and material-related hypersensitivity were considered. Inflammatory markers were only moderately elevated, peripheral eosinophilia was documented, dermatologic assessment favored a hypersensitivity reaction, and surgical exploration showed extensive inflammatory and fibrotic tissue around the graft without macroscopic purulence. The PTFE graft was completely removed, the AVF was ligated, and the brachial artery was repaired directly. Histopathology demonstrated a prominent eosinophil-rich inflammatory infiltrate with polymorphonuclear cells. The cutaneous reaction regressed rapidly after graft explantation, and hand function recovered fully. Hemodialysis was continued through a tunneled central venous catheter. This case illustrates that severe postoperative inflammation around a PTFE vascular graft should prompt consideration of material-related hypersensitivity alongside infection and supports early graft removal when a progressive reaction is clinically severe and the prosthesis is the suspected trigger.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bioengineered Vascular Grafts for Hemodialysis Access: Design Requirements, Clinical Evidence, and Translational Barriers.ACS biomaterials science & engineering · 2026
- Successful endovascular and staged hybrid salvage of dialysis access after spontaneous disconnection of super-HeRO graft adapter and early-cannulation graft.The journal of vascular access · 2026
- Fatal invasive fungal infection morphologically consistent with aspergillosis accompanied by vascular graft infection and marked eosinophilia after thoracic endovascular aneurysm repair.Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy · 2026
- Comparative analysis of femoral vein translocation and upper extremity grafts for hemodialysis accessThe Journal of Vascular Access · 2026
- Venous Hypertension Associated with an Abnormal Configuration of a Protruding Cephalic Arch Stent in Arteriovenous Haemodialysis Access: A Case Report.EJVES vascular forum · 2026
- Endogenous tissue restoration in a hemodialysis conduit: Performance and safety after 1-year of follow-upThe Journal of Vascular Access · 2025