How Pilot Tone Senses Cardiac Motion: Theory, Electromagnetic Simulation, and In Vivo Validation
Mario Bacher, Matthias Stuber, Peter Speier
Key points
From the paper's conclusion- We performed electromagnetic simulations on a realistic digital human phantom simulating cardiac motion and demonstrated in silico how eddy currents in conductive tissues lead to the generation of a secondary magnetic field, which can be sensed by coil arrays of commercial MRI systems.
Abstract
Purpose The pilot tone (PT) is a novel electromagnetic sensor that enables contactless respiratory and cardiac motion sensing for clinical MRI. Here, we aim to present the first full‐wave electromagnetic simulation framework for investigating the physical processes underlying the PT navigator using a realistic digital human phantom, and to validate the resulting predictions against in vivo measurements. Methods We developed an analytical framework—a volume integral formulation and a simplified equivalent circuit model—that describes how tissue motion modulates the received signal and provides physical intuition of the coupling mechanism. We performed electromagnetic simulations on a realistic digital human phantom simulating cardiac motion and demonstrated in silico how eddy currents in conductive tissues lead to the generation of a secondary magnetic field, which can be sensed by coil arrays of commercial MRI systems. We showed how the received signal modulation is distributed spatially in the scan volume and validated the simulation experimentally by S‐parameter measurements in three volunteers. Results Differences in conductivity between tissues and their movement during the cardiac cycle are the driving force behind the observed PT signal modulation. Simulations showed expected signal modulation trends and provided mechanistic insight into how signal modulation due to cardiac motion can be sensed. The simulated signal modulation strongly correlated with total cardiac volume (| R |>0.94). S ‐parameter measurements in three volunteers corroborated the simulation, with cardiac modulation detected in all receive channels and modulation depths and spatial patterns broadly consistent with the simulation results. Conclusion Our analytic and simulation models demonstrate how inductive coupling shapes the PT signal and provide mechanistic understanding of the modulation process. These results were validated by in vivo experiments. The modulation patterns generated by tissue motion make PT an attractive technique for measuring physiological motion independently of sequence parameters and trajectory while being both easy to use and requiring no patient preparation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Continuous and Wireless Monitoring of Myocardial Dynamics Using Biocompatible Magneto-Viscoelastic Patches.Advanced materials (Deerfield Beach, Fla.) · 2026
- H ygieia : A Wearable Metamaterial Patch for Calibration-free Carotid Hemodynamics MonitoringProceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · 2026
- Model-based cardiac field artefact correction for OP-MEG.Imaging neuroscience (Cambridge, Mass.) · 2026
- Haptic and Palpation Sensing for Robotic Surgery: Engineering Perspectives on Design and IntegrationSensors · 2026
- A physics-informed eikonal model for simulating arrhythmias in the human heart in real-time.Nature communications · 2026
- Sensing Life in Stillness: Unified Dynamic and Static Human Mesh Reconstruction with mmWave RadarProceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · 2026