Cardiovascular therapeutics

Comparative Performance of Calcium-Modification Strategies for Coronary Lesions: A Network Meta-Analysis of Randomized Trials.

Fiorenzo Simonetti, Andreas T Kristensen, Tobias Lenz, Felix Voll, Moritz von Scheidt, Michael Joner, Tobias Rheude, Hendrik Sager,

Department of Cardiovascular Diseases, TUM Klinikum Deutsches Herzzentrum, Technical University of Munich, Munich, Germany, tum.de. · Department of Cardiology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark, rigshospitalet.dk.

Meta-analysis

Key points

From the paper's conclusion
  • Compared with standard noncompliant balloons, RA and balloon-based strategies improved the mechanical performance of PCI in calcified coronary lesions. However, this did not result in better clinical outcomes.

Abstract

INTRODUCTION AND OBJECTIVES: Calcified coronary lesions are associated with an increased risk of percutaneous coronary intervention (PCI) failure. Despite the availability of several calcium-modification strategies and randomized trials evaluating their efficacy, comparative investigations remain scanty. The aim of the present analysis is to assess the comparative performance of calcium-modification strategies in patients undergoing PCI of calcified coronary lesions. METHODS: We conducted a systematic search for randomized trials evaluating calcium-modification strategies in patients undergoing PCI. Random-effects network meta-analyses were performed. The primary outcome was minimal stent area (MSA). Secondary outcomes included all-cause death and stent thrombosis. RESULTS: Twenty-two trials enrolling 4855 patients were included. Compared to calcium modification with noncompliant balloons, the use of cutting/scoring balloon (mean difference: 0.81 mm2, 95% confidence interval: [0.36, 1.27]; p = 0.001), super high-pressure balloon (SHPB, 0.95 mm2 [0.18, 1.72]; p = 0.016), intravascular lithotripsy (IVL, 0.87 mm2 [0.40, 1.34]; p < 0.001), rotational atherectomy (RA, 0.90 mm2 [0.30, 1.50]; p = 0.003), and RA plus cutting balloon (1.24 mm2 [0.46, 2.02]; p = 0.002) led to larger MSA. According to a network ranking analysis, RA, SHPB, and IVL were possibly the best treatment options in terms of MSA. There were no significant differences in clinical outcomes between calcium-modification strategies. CONCLUSIONS: Compared with standard noncompliant balloons, RA and balloon-based strategies improved the mechanical performance of PCI in calcified coronary lesions. However, this did not result in better clinical outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers