Geometry-Driven Biomechanical Optimization of Double-J Ureteral Stents.
Achmad Syaifudin, Mudhita Zikkrullah Ritonga, Lukman Hakim, Mohamad Taufiqurrakhman, Hemant Pandit
Department of Medical Technology, Institut Teknologi Sepuluh Nopember, Surabaya, Indonesia, its.ac.id. · Faculty of Veterinary Medicine, Universitas Syiah Kuala, Banda Aceh, Aceh, Indonesia, unsyiah.ac.id.
Key points
From the paper's conclusion- This framework provides a structured basis for future finite element analysis, computational fluid dynamics, and fluid-structure interaction studies, followed by experimental and clinical validation, to quantitatively evaluate coil orientation as a complementary geometric variable in double-J ureteral stent design and development.
Abstract
Ureteric stents are widely used to maintain ureteric patency; however, complications such as stent migration, ureteric irritation, and patient discomfort remain common. Although several geometric parameters of double-J stents have been investigated in relation to urinary flow, stenosis, reflux, encrustation, stent length, and coil characteristics, the specific biomechanical role of terminal coil orientation relative to physiological loading remains insufficiently characterized. This study proposes a geometry-based biomechanical framework that considers terminal coil-plane orientation as a specific and mechanistically insufficiently characterized geometric variable in double-J ureteral stent stability. The framework integrates biomechanical principles, engineering concepts, and clinical considerations to provide a simplified mechanistic interpretation of how coil geometry may interact with multidirectional physiological loading generated by ureteral peristalsis and intravesical pressure. Changes in coil-plane orientation may alter the transmission and decomposition of physiological forces, potentially influencing axial loading, transverse forces, bending response, stent-wall contact, and resistance to longitudinal displacement. An alternative terminal coil-plane orientation is proposed as a testable geometric modification that may alter these mechanical relationships without changing the overall dimensions or material composition of the device. The proposed relationships are conceptual and do not represent validated stress distributions, experimentally demonstrated retention benefits, or evidence that any particular coil orientation is superior. This framework provides a structured basis for future finite element analysis, computational fluid dynamics, and fluid-structure interaction studies, followed by experimental and clinical validation, to quantitatively evaluate coil orientation as a complementary geometric variable in double-J ureteral stent design and development.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Choosing the optimal ureteral stent design, size, and material in different situations: a review from the European association of urology endourology.World journal of urology · 2026
- From biofilms to fibrosis: recent advances in research on the pathological microenvironment linked to ureteral stents and their surface functionalization.Frontiers in bioengineering and biotechnology · 2026
- Mechanical interactions between airway stents and the airway wall: biomechanics, complications, and design optimizationJournal of Materials Science: Materials in Engineering · 2026
- Slippery when wet: The effect of a novel zwitterionic coating on silicone ureteral stents.Urolithiasis · 2026
- Severe Encrustation, Fragmentation, and Urethral Extrusion of a Forgotten Ureteral Stent Managed With a Minimally Invasive Approach.Clinical case reports · 2026
- EndoForce: An Axial Force Sensing Device Inspired by Clinical Insertion Motion for Endoscopic Robotic SystemsApplied Sciences · 2026