Triclosan Surface Coating Inhibits Bacterial Attachment: In Vitro Assessment for Prosthetic Joint Infection Prevention.
Julia L van Agtmaal, Laura C W Peeters, David Armbruster, Jan Geurts, Rajendra Kasinath, Jacobus J C Arts
Department of Orthopedic Surgery, Research Institute CAPHRI, Maastricht University Medical Center, Maastricht, the Netherlands, mumc.nl. · DePuy Synthes Biomaterials, Warsaw, Indiana, USA.
Key points
From the paper's conclusion- This study examined the use of the synthetic broad-spectrum antimicrobial agent triclosan (2, 2, 4 '-trichloro-2 '-hydroxyphenyl ether) to prevent bacterial attachment on titanium (Ti) and ultrahigh-molecular-weight polyethylene (UHMWPE) substrates without a carrier by vaporizing it in a reservoir.
Abstract
Approximately 2% of primary and 30%-40% of revision arthroplasties lead to prosthetic joint infection (PJI). Biofilm formation and antimicrobial resistance decrease bacterial susceptibility to antibiotics. This study examined the use of the synthetic broad-spectrum antimicrobial agent triclosan (2, 2, 4 '-trichloro-2 '-hydroxyphenyl ether) to prevent bacterial attachment on titanium (Ti) and ultrahigh-molecular-weight polyethylene (UHMWPE) substrates without a carrier by vaporizing it in a reservoir. Triclosan loading on Ti and UHMWPE and release from Ti samples was assessed over 21 days. In vitro antimicrobial activity against S. aureus and E. coli was tested according to standards ISO 22196, ASTM E 2180-18, and JIS Z 2801 for regulatory compliance, followed by bacterial adhesion tests in suspension. Cell viability was assessed following ISO 10993-5 standards using WST-1 and LDH assays with L929 cells (ATCC cell line CCL 1, NCTC clone 929) in a static test on extract. The target loading of 0.15 mg/cm2 was achieved on Ti (0.15 mg/cm2), whereas UHMWPE reached 0.03 mg/cm2. The 21-day release test on Ti samples showed an initial burst of 0.05 mg/cm2 on Day 1. The cumulative release was 0.126 mg/cm2 (84% of the total dose), indicating continuous triclosan release and availability. Both antimicrobial tests and bacterial strains showed a reduction of 3.70-6.18 logs in bacterial count for the triclosan-coated samples compared with uncoated ones. Triclosan was more effective against S. aureus than E. coli. The Ti samples showed slightly higher reductions than UHMWPE. Triclosan exhibited low cell viability (4.1%-41.2%) and high cytotoxicity (up to 97.8%) across all tested extract concentrations. Although the triclosan coating demonstrated a significant bacteriostatic and bactericidal effect, results from static 2D cell viability assays raise concerns at this dose level. Further research using dynamic in vitro or in vivo systems is necessary to investigate the balance between the antibacterial efficacy and the toxic effects of triclosan.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In vitro assessment of antibacterial and biocompatibility properties of a poly-ε-lysine and hyaluronic acid contact-killing coating to prevent prosthetic joint infectionPLoS ONE · 2026
- Ciprofloxacin-loaded poly(lactic acid) coating on polyurethane ureteral stents: surface structure, antibacterial performance and encrustation resistance.RSC advances · 2026
- Biofilm Removal and Bacterial Reduction Using a Low-Cost Ultrasonic Bath Sonicator with Povidone-Iodine on Polyethylene: An In Vitro Periprosthetic Joint Infection Model.Antibiotics (Basel, Switzerland) · 2026
- Antimicrobial efficiency of pH-responsive PAA/PAH-coated and flucloxacillin loaded titanium implants in the Galleria mellonella model.Drug delivery and translational research · 2026
- Antibiotic-Loaded Porous Titanium Antibacterial Particle Coatings by High-Velocity Embedment into Silicone.ACS biomaterials science & engineering · 2026
- Photoresponsive Bilayer Coating Integrating a Porous Zinc Oxide Layer and a Chitosan-Antibiotic Drug Delivery System for Antimicrobial Photodynamic Therapy in Biomedical Implants.ACS materials Au · 2026