Advances in Civil Engineering

Macro‐Modelling of Perforated Block Masonry‐Infilled Reinforced Concrete Frames: Calibration Against Simplified Micro‐Models and Structural Similitude

Arton D. Dautaj, Milot Muhaxheri

Key points

From the paper's conclusion
  • The reduced‐scale study then delimits what a similitude comparison can demonstrate: a strut macro‐model contains no length scale and satisfies the similarity relationships identically, whereas the micro‐model departs from them by up to 4.5%, and that departure is the measurable size effect.

Abstract

Macro‐models based on equivalent diagonal struts are the only practical option for the structural‐scale analysis of masonry‐infilled reinforced concrete (RC) frames, but their parameters, above all the effective strut width, are empirical, were calibrated almost exclusively on solid units and cannot be measured directly; experimental calibration is scarce because each point requires a full‐scale frame test. This article proposes simplified micro‐modelling (SMM) of perforated block masonry as the technique that supplies them. Perforated clay blocks are replaced by equivalent solid units expanded by the mortar thickness, the joints are reduced to zero‐thickness cohesive interfaces with tensile and shear yield criteria, and the continuum is governed by a concrete damage plasticity (CDP) law. Replacing the perforated unit removes the constraint its thin internal shells impose on the explicit time increment, while the expanded‐unit properties come from small prism and wall‐panel tests or from Eurocode 6 expressions and are used without user subroutines. The technique reproduces the capacity, stiffness and observed failure mechanisms of two quasi‐static tests on perforated clay block infilled RC frames to within 10%–12%; a third was reproduced with the same technique in earlier work. The validated model is then the reference from which an equivalent‐strut macro‐model is calibrated: three parallel compression‐only struts on a fibre frame in OpenSees. On Specimen 13 the envelope is identified from the measured backbone and the model returns the peak base shear to within 0.6% with a whole‐curve error of 2.1%; in every validation case the envelope is generated from the masonry properties and one quantity only is fitted, the dimensionless strut width. Calibrated on a single one‐bay frame, that parameter transfers unchanged to two‐ and three‐bay frames with a mean absolute error of 2.5% in peak base shear and a maximum of 3.1%, verified on complete curves rather than peaks, and is conservative by 8%–16% when carried to six‐storey frames. The calibrated width increases with the quality of the masonry, from 0.193 to 0.294 of the panel diagonal, whereas a width defined through a stiffness parameter alone falls from 0.152 to 0.129 over the same range; the three levels examined vary strength, modulus and strains together and cannot separate them. Column shear links following expression A.12 of EN 1998‐3 show the configuration with the smallest drift to be the one whose columns fail, so for frames of these proportions the governing limit state is local; a sensitivity study over seven distributions of the infill thrust among the struts, and over ±20% on every calibrated quantity, leaves that conclusion standing and identifies the strut width as the one quantity it depends on. The reduced‐scale study then delimits what a similitude comparison can demonstrate: a strut macro‐model contains no length scale and satisfies the similarity relationships identically, whereas the micro‐model departs from them by up to 4.5%, and that departure is the measurable size effect.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers